17
GB
Note:
If you are not able to push the
protective glass
11
in fully, gently press
on the outside of the protective glass
11
.
z
Using the device
Note:
The welding device is designed
for welding with electrodes.
Use the electrode holder clamps with-
out protruding bracket screws, which
meet the current safety standards.
Make sure that the ON/OFF switch
9
is set to position “O” (“OFF”)
or that the power cable
10
is not
plugged into the socket.
Connect the welding cable accord-
ing to its polarity and in accordance
with t
he specifications of the elec-
trode manufacturer.
To do this, connect the connector of
the earth terminal
4
(black) with the
relevant output on the inverter welder
(black, marked with “-”).
Connect the connector of the elec-
trode holder
5
(red) with the
relevant output on the inverter welder
(red, marked with “+”).
Put on appropriate protective
clothing in accordance with the
specifications and prepare your
workspace.
Connect the earth terminal
4
to the
workpiece.
Clamp the electrode into the elec-
trode holder
5
.
Switch the device on by setting the
ON/OFF switch to the
9
“I” (“ON”)
position.
Adjust the welding current using the
rotary knob
2
depending on the
electrode being used.
Note:
See the following table for
information on the welding current to
be used, depending on the electrode
diameter.
Ø Electrode
Welding current
1.6 mm
40 – 55 A
2.0 mm
55 – 65 A
2.5 mm
65 – 80 A
3.2 mm
80 – 120 A
Attention:
Do not bring the earth
terminal
4
and the electrode holder
5
/
electrodes into direct contact with one
another.
Attention:
When welding with
electrodes (MMA – manual metal arc
welding – electrode welding), the
electrodeholder
5
and the earth
terminal
4
must be connected in
accordance with the specifications of
the electrodes to plus (+) or minus (-).
Hold the welding mask
7
in front of
the face and start the welding
procedure.
To stop the procedure, set the ON/
OFF switch
9
to “O” (“OFF”)
position.
ATTENTION!
When the thermal sensor is triggered,
the yellow control lamp
3
lights up. In
this case, it will not be possible to
continue welding. The device will
remain in operation so that the fan can
cool the device. As soon as the device
is ready for operation again, the yellow
control lamp
3
will switch off automati-
cally. The welding function can now be
used again.
ATTENTION!
Make sure that you do not rub the
electrodes. Doing this can damage the
workpiece and make it more difficult to
ignite the arc. After the arc is ignited,
maintain the correct gap from the
workpiece. The distance should be
appropriate to the diameter of the