background image

GB/IE

Introduction

Introduction / General  safety  rules

  

Technical Data

Max.  torque: 

61 Nm

Operating  pressure: 

6.3 bar

Speed: 

160 min

-1

Weight: 

1120 g

Noise and vibration

Noise ratings were determined according to  
EN 15744. Vibration ratings were determined  
according to ISO 28927-2.

Vibration  
(per  EN  28927-2): 

2.63 m / s

Uncertainty  K: 

1.5 m / s

2

Noise level L

pA

91.9 dB(A)

Uncertainty K

pA

3 dB

Sound power level L

WA

:  102.9 dB(A)

Uncertainty K

WA

3 dB

L

pC, peak

 = 105.3 dB(A)

Uncertainty K = 3 dB

  

Scope of delivery

1  Air ratchet set
1  Plug nipple with gasket
7  Socket key (10, 11, 13, 14, 15, 17, 19 mm)
1 Extension 
3  Bits (PH 2.3, SL 5.5)
1 U-joint
1  Bit holder
1  Oil reservoir
1  Carrying case
1  Instructions for use

 General safety rules

Note: 

When used in the following text, the terms 

„compressed air unit“ or „device“ refer to the com-
pressed air unit specified in these instructions for use.

 Basic safety measures must be 

followed when using compressed air units to eliminate 
the risk of fire, electric shock and personal injury. 
Be sure to read and follow the notices within these 

operating instructions prior to using the equipment 
and store them in a safe location. 
The manufacturer assumes no liability for damages 
or personal injury resulting from failure to follow these 
operating instructions.

  

Persons (including children) who lack the knowl-
edge or experience to use the tool or whose 
physical, sensory or intellectual capacities are 
limited must never be allowed to use the tool 
without supervision or instruction by a person 
responsible for their safety.

  

Ensure children do not play with the device.

  

 

RISK OF INJURY!

 Before 

performing maintenance tasks, disconnect the 
compressed air supply.

  

EXPLOSION HAZARD! 

Never 

use petrol or other flammable liquids 
to clean the air tool! Sparks could 

ignite residual vapours inside the compressed 
air unit resulting in the compressed air unit ex-
ploding. Do not use the device in explosive en-
vironments with flammable liquids, gasses or dust. 
Never work on materials which are or could 
potentially be highly flammable or explosive.

  

Only use the equipment in areas of application 
for which it was designed!

  

Do not overburden the device.

  

Never use hydrogen, oxygen, carbon 
dioxide or other bottled gasses to 
power this tool as doing so may re-

sult in an explosion and thus may cause severe 
injuries.

  

Regularly maintain and clean the device as 
specified (see chapters „Maintenance“ and 
„Cleaning and care“).

  

Inspect the device for any damage before use. 
Always make sure that the device is in perfect 
condition each time before use.

  

Always be attentive! Unexpected movement of 
the device may cause hazards.

  

Avoid placing your body in an unnatural position. 
Keep proper footing and balance at all times. 
By doing this you will be in a better position to 
control the compressed air unit in unforeseen 
circumstances.

Summary of Contents for PDRS 6.3 A1

Page 1: ...ENSCHRAUBER Bedienungs und Sicherheitshinweise Originalbetriebsanleitung PNEUMATIC RATCHET SET Operation and Safety Notes Translation of the original instructions TRYKLUFT SKRALDES T Brugs og sikkerhe...

Page 2: ...ore reading unfold the page containing the illustrations and familiarise yourself with all functions of the device F r du l ser vend siden med billeder frem og bliv bekendt med alle apparatets funktio...

Page 3: ...A B 1 3 2 4 C 5 6 7 8 9 10 11...

Page 4: ...Workplace hazards Page 10 Dust and fume hazards Page 10 Noise hazards Page 11 Vibration hazards Page 11 Additional safety instructions for pneumatic power tools Page 11 Start up Page 12 After initial...

Page 5: ...e place When passing this product on to others please also include all the documents Any use other than the intended is prohibited and potentially dangerous Damages resulting from noncompliance or mis...

Page 6: ...edge or experience to use the tool or whose physical sensory or intellectual capacities are limited must never be allowed to use the tool without supervision or instruction by a person responsible for...

Page 7: ...replaced by the manufacturer or its service department or a similarly qualified per son in order to avoid hazards Do not use the device when tired or under the influence of drugs alcohol or medicatio...

Page 8: ...difications can reduce the effectiveness of safety measures and increase the risks to the operator Do not discard the safety instructions give them to the operator Do not use the assembly power tool f...

Page 9: ...sembly power tool for threaded fasteners from the energy supply before chang ing the inserted tool or accessory Do not touch sockets or accessories during im pacting as this increases the risk of cuts...

Page 10: ...ell your employer and consult a phy sician Operate and maintain the assembly power tool for threaded fasteners as recommended in the instructions handbook to prevent an unneces sary increase in vibrat...

Page 11: ...attached to the compressor Manually Add 3 5 drops of speciality tool oil to the compressed air connection before every use If the compressed air tool is not being used for several days add 5 10 drops...

Page 12: ...roduct please have your receipt and product number e g IAN ready as your proof of purchase The product number can be found on the type plate an engraving the cover page of your instructions bottom lef...

Page 13: ...hat the product Pneumatic ratchet set Item number 1935 Year of manufacture 2016 34 IAN 275669 Model PARKSIDE PNEUMATIC RATCHET SET PDRS 6 3 A1 meets the basic safety requirements of European Directive...

Page 14: ...eh rsdele Side 20 Farer p arbejdspladsen Side 20 Fare p grund af st v og dampe Side 21 Farer p grund af larm Side 21 Farer ved svingninger Side 21 Yderligere sikkerheds anvisninger til pneumatiske mas...

Page 15: ...geligt Hvis De giver produktet videre til andre skal vejledningen ogs f lge med Enhver anvendelse der afviger fra den form lsbestemte anvendelse er for budt og indeb rer potentielle farer Skader der o...

Page 16: ...oldt h fter producenten ikke Dette apparat er ikke egnet til anvendelse af personer b rn indbefattet med begr nsede fysiske sensoriske og mentale evner eller med manglende erfaring og eller viden om a...

Page 17: ...kluftsslange der sl r omkring sig hvilket der med kan resultere i kv stelser N r dette apparats tilslutningsledning beskadi ges s skal den erstattes af producenten eller dennes kundeservice eller af e...

Page 18: ...kinen p begyndes Ellers kan det resultere i alvorlige kv stelser Maskinen til skrueforbindelser b r udelukkende installeres indstilles eller bruges af kvalificerede og skolede brugere Der m ikke foret...

Page 19: ...dtag en behagelig stilling n r du arbejder med denne maskine v r opm rksom p et stabilt fodf ste og undg ufordelagtige positi oner eller s danne hvor det er vanskeligt at holde balancen Brugeren skal...

Page 20: ...orbindelser skal drives og vedligeholdes iht anbefalingerne i denne vej ledning for at undg et un digt h jt st jniveau R der maskinen til skrueforbindelser over en lydd mper s skal du sikre at denne b...

Page 21: ...ejder Ibrugtagning se afbildning B C Skru den medleverede stiknippel 4 i lufttilslut ningen efter at De forinden har viklet 2 3 lag t tningsb nd ikke indeholdt i leveringen p gevindet Stik den n dvend...

Page 22: ...lsomme komponenter som f eks kontakter batterier eller dele af glas Garantien bortfalder hvis apparatet bliver beskadi get eller ikke anvendes eller vedligeholdes korrekt Til en korrekt anvendelse af...

Page 23: ...kke mere funktionsdygtige apparater genbruges Sp rg om r d hos deres lokale forhandler EG konformitetserkl ring Vi virksomheden C M C GmbH Dokumentansvarlig Daniel Havener Katharina Loth Str 15 66386...

Page 24: ...teile Seite 31 Gef hrdungen am Arbeitsplatz Seite 31 Gef hrdungen durch Staub und D mpfe Seite 31 Gef hrdungen durch L rm Seite 32 Gef hrdungen durch Schwingungen Seite 32 Zus tzliche Sicherheitsan we...

Page 25: ...ie beschrieben und f r die angegebenen Einsatzbereiche Bewahren Sie diese Anleitung gut auf H ndigen Sie alle Unterla gen bei Weitergabe des Produkts an Dritte ebenfalls mit aus Jegliche Anwendung die...

Page 26: ...und beachten Sie unbedingt vor der ersten Inbetriebnahme die Hinweise dieser Betriebsanleitung und bewahren Sie diese gut auf F r Sch den oder K rperverletzungen die entstehen weil diese Betriebsanle...

Page 27: ...zhelm oder Geh rschutz je nach Art und Einsatz des Druckluftwerkzeugs verrin gert das Risiko von Verletzungen Pr fen Sie Anschl sse und Versorgungsleitungen S mtliche Wartungseinheiten Kupplungen und...

Page 28: ...hren Dadurch k nnen Sie das Ger t insbesondere in unerwar teten Situationen besser kontrollieren Lassen Sie das Ger t nur von qualifiziertem Fachpersonal und nur mit Original Ersatzteilen reparieren D...

Page 29: ...ieb fern Gef hrdungen im Betrieb Beim Einsatz der Maschine k nnen die H nde der Bediener Gef hrdungen durch Quetschen Schlagen Schneiden Abrieb und W rme aus gesetzt sein Tragen Sie geeignete Handschu...

Page 30: ...mit Schlagschraubern zerbrechen und herausgeschleudert werden Gef hrdungen am Arbeitsplatz Ausrutschen Stolpern und St rzen sind Haupt gr nde f r Verletzungen am Arbeitsplatz Achten Sie auf Oberfl che...

Page 31: ...chwingungen Die Einwirkung von Schwingungen kann Sch di gungen an den Nerven und St rungen der Blut zirkulation in H nden und Armen verursachen Halten Sie ihre H nde von den Fassungen der Mutterndrehe...

Page 32: ...chmesser des Schlauches festgelegt werden Tragen Sie mit Luft arbeitende Maschinen nie mals am Schlauch Inbetriebnahme s Abb B C Schrauben Sie den mitgelieferten Stecknippel 4 in den Luftanschluss nac...

Page 33: ...en haft gepr ft Die Garantieleistung gilt f r Material oder Fabrika tionsfehler Diese Garantie erstreckt sich nicht auf Produktteile die normaler Abnutzung ausgesetzt sind und daher als Verschlei teil...

Page 34: ...Zubeh r und Verpackung sollten einer umweltgerechten Wiederverwer tung zugef hrt werden Werfen Sie das Druckluftwerkzeug nicht in den Haus m ll ins Feuer oder ins Wasser Wenn m glich sollten nicht meh...

Page 35: ...C M C GmbH Katharina Loth Str 15 66386 St Ingbert Germany Last Information Update Tilstand af information Stand der Informationen 04 2016 Ident No PDRS 6 3 A1 042016 6 IAN 275669...

Reviews: