Technical specifications
Rated air pressure:
max . 6 .8 bar
Air consumption:
720 l/min
Max . rotation speed: max . 1800 rpm
Tool fitting:
max . Ø 10 mm
(wheel-rim chuck)
Noise emission values:
Noise measurement determined in accordance
with ISO 15744:
Sound pressure level: L
pA
= 87 .9 dB (A)
Uncertainty: K
pA
= 3
dB
Sound power level: L
WA
= 98 .9 dB (A)
Uncertainty:
K
WA
= 3 dB
Wear hearing protection!
Vibration emission value:
Vibration values determined in accordance with
ISO 28927-5 and EN 12096:
a
h
= 0 .98 m/s
2
Uncertainty K = 0 .59 m/s
2
WARNING!
►
The noise emission levels specified in these
instructions have been measured in ac-
cordance with the standardised measuring
procedure specified in ISO 15744 and can
be used to make equipment comparisons .
The noise emission values vary in accordance
with the use of the compressed-air tool and
may be higher than the values specified in
these instructions in some cases . It is easy to
underestimate the noise emission load if the
compressed-air tool is used regularly in a
certain manner .
NOTE
►
For an accurate estimate of the noise emission
load during a certain working period, the
times during which the tool is switched off or
is running but not actually being used must
also be taken into consideration . This can
significantly reduce the noise emission load
over the total working period .
WARNING!
General safety instruc-
tions for compressed-air
tools
WARNING!
►
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious
injury .
NOTE
►
The terms “compressed-air tool" or "tool" used
in the following text refer to the compressed-air
tools specified in these operating instructions .
Save all warnings and instructions for future
reference.
■
The user must evaluate the specific risks that
may arise due to different kinds of use .
■
Please ensure that you have read and under-
stood the safety instructions before fitting,
operating, repairing, servicing or replacing
any accessories and before working near the
compressed-air tool . Failure to do this can result
in serious bodily injury .
■
The compressed-air tool should only be set up,
adjusted or used by adequately qualified and
trained operators .
■
The compressed-air tool may not be modified .
Modifications can reduce the effectiveness of
the safety measures and increase the risks for
the operator .
■
Never use damaged compressed-air tools .
Maintain compressed-air tools with care . Check
regularly whether moving parts function correctly
and do not jam; check whether any parts are
broken or damaged to an extent that the com-
pressed-air tool will no longer operate correctly .
Check signs and labels for completeness and
readability . If damaged, have parts repaired
or replaced before using the compressed-air
tool . Many accidents are caused by poorly
maintained compressed-air tools .
Summary of Contents for PDBS 1800 A1