PDBS 1800 A1
GB
│
IE
│
NI
│
11
■
Before use
NOTE
►
The compressed-air tool may only be operat-
ed using cleaned, oil-atomised compressed
air and the maximum operating pressure of
6 .8 bar must not be exceeded on the tool .
The compressor must be fitted with a pressure
reducer to regulate the working pressure .
Lubrication
WARNING!
►
Inform yourself about the health hazards of
the oil used in the safety data sheet of the
respective manufacturer .
NOTE
►
Regular lubrication is particularly important to
avoid friction and corrosion damage .
We recommend using a suitable special oil
for compressed-air tools (e .g . Liqui Moly
compressor oil) .
–
Lubrication with mist oiler
A mist oiler (not supplied) continuously
and optimally lubricates the grinder as a
preparation stage after the pressure re-
ducer . A mist oiler gives off fine drops of
oil into the air flow and thus guarantees a
regular lubrication .
–
Manual lubrication
If you do not have a mist oiler, lubricate
the tool before every use or longer work
sessions . Add 3–4 drops of pneumatic
oil into the connector nipple .
Refilling oil
To ensure that the tool remains operational for
a long time, it must have a sufficient supply of
pneumatic oil .
You have the following options:
♦
Attach a maintenance unit with an oiler to the
compressor .
♦
Install a fitted oiler into the compressed-air line
or the compressor .
♦
Add 3–5 drops of pneumatic oil into the
connector nipple after every 15 minutes of
operation .
Connecting to a compressed-air
source
NOTE
►
Before connecting the compressed-air source
–
the correct working pressure (3–6 .8 bar)
must be fully reached, and
–
you must ensure that the trigger is in the
upper position
►
Use only connection hoses with an internal
diameter of at least 9 mm .
►
Use only filtered, lubricated and regulated
compressed air .
♦
Attach the tool to a compressor by connecting
the connector nipple with the supply hose of
the compressed-air source .
CAUTION!
►
Ensure that the compressed-air hose is firmly
attached . A loose hose can thrash about
uncontrollably causing grave danger . Likewise,
ensure the firm seat of the two screw connec-
tions between the coupling piece and the tool .
♦
The compressed-air source must be equipped
with a pressure reducer so that you can regulate
the air pressure .
Summary of Contents for PDBS 1800 A1
Page 3: ......