5. CONNECTING TO GAS
This appliance is designed to be installed with an
appliance flexible connection only. Supply piping should
not be less than R³/8 (³/8" B.S.P.). Connection is made
to the Rc½ (½" B.S.P.) female threaded entry pipe
located just below the hotplate level on the rear left hand
side of the appliance.
Check for gas soundness after connecting the gas
supply.
The gas bayonet connector must be fitted in the shaded
area indicated in Fig. 5. Take into account that it must
be possible to pull the appliance forward sufficiently.
The hose must not get caught on the stability bracket.
IMPORTANT: FLEXIBLE TUBING USED MUST
COMPLY WITH BS. 669 CURRENT EDITION. L.P.G. FLEXIBLE CONNECTIONS MUST BE OF A TYPE
SUITABLE FOR L.P.G. AND CAPABLE OF OPERATION UP TO 50MBAR AND TO CARRY A RED
STRIPE, BAND OR LABEL.
NOTE: ONLY LIQUID SEALANTS CAN BE USED IN THREADED GAS CONNECTIONS. DO NOT USE
P.T.F.E. TAPE.
6. CONNECTION TO THE ELECTRICITY SUPPLY
WARNING: THIS APPLIANCE MUST BE EARTHED. DO NOT EARTH THIS APPLIANCE TO THE GAS
SUPPLY PIPING.
This appliance must be connected to 220V-240V A.C. 50 Hz supply. It is supplied with 2 metres of 5 amp 3
core cable incorporating a moulded 13 amp rated plug, fitted with a 3 amp fuse, which can be plugged directly
into the nearest suitable socket. If this is not long enough, the supply cable can either be:-
(i)
Replaced totally by a longer cable at least 0.75mm
2
nominal cross sectional area (24/0.2mm).
(ii)
Extended by using a B.E.A.B. approved 3-way sealed flex connector with integral flex clamps.
IF THE MOULDED PLUG IS CUT FROM THE CABLE FOR ANY REASON, IT
MUST BE DESTROYED OR DISPOSED OF SAFELY, AS THE PROTRUDING
WIRES WILL BE AN ELECTRIC SHOCK HAZARD.
If any other type of plug is used it should incorporate a 5 amp fuse in either the plug or at the distribution
board. If the cable has to be threaded through small apertures in cabinets etc., it may be disconnected from
the appliance, then re-connected as shown in Fig.6.
DO NOT EXTEND THE CABLE USING PLASTIC OR CERAMIC CONNECTION TERMINAL BLOCKS
AND/OR INSULATION TAPE.
ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL
COMPLY WITH I.E.E. WIRING REGULATIONS.
I
f the wiring is extended or a completely new cable fitted a 3-pin 13A plug should be fitted. (See Fig.6a).
Connect the wires as follows:-
BROWN to the Live Terminal.
BLUE to the Neutral Terminal.
GREEN AND YELLOW to the Earth Terminal.
40
R E N O W N 5 5 G X
Fig.5
Fig.6
200
400
400
250
All dimensions in mm