Key Switch
If a fault happens to appear on the controller that relates to a safety device the gate will more than
likely only operate in deadman mode. on the front of the tower there is a key switch that can be
turned either way to open the gate in deadman operation overriding the faults. if you let go of the
key switch whilst the gate is operating the gate will stop until you continue turning the keyswitch. if
there is no fault on the gate the key switch will give a normal automatic open and close signal.
If you have two gates working in master and slave mode the key switch will only operate the gate
that it is attached to.
Stop Button
If you have an issue and need to stop the gate immediately there is a stop button on the gate that
will stop the gate and will not allow it to operate until its released. once pressed in you twist the
button and it will release.
once released you will need to give the gate another open or close signal
for it to start operating again.
If you have two gates working in master and slave mode the stop button will only operate the gate
that it is attached to.