English
SPL040-060
3 / 4
6 Maintenance
a) Th
e machine is designed and built to guarantee continuous opera-
tion; however, the life of its components depends on the mainte-
nance performed;
b) when requesting assistance or spare parts, identify the machine
(model and serial number) by reading the data plate located on the
unit.
6.1 General instructions
!
Before any maintenance, make sure:
• the pneumatic circuit is no longer pressurized;
• the dryer is disconnected from the main power supply
.
Y
Always use the Manufacturer’s original spare parts: otherwise the
Manufacturer is relieved of all liability regarding machine malfunction-
ing
Y
In case of refrigerant leakage, contact qualifi ed and authorized per-
sonnel.
Y
Th
e Schrader valve must only be used in case of machine malfunc-
tion: otherwise any damage caused by incorrect refrigerant charging will
not be covered by the warranty.
6.2 Refrigerant.
Charging: any damage caused by incorrect refrigerant replacement car-
ried out by unauthorized personnel will not be covered by the warranty.
Z
Y
Th
e equipment contains fl uorinated greenhouse gases.
At normal temperature and pressure, the R134a refrigerant is a colour-
less gas classifi ed in SAFETY GROUP A1 - EN378 (group 2 fl uid ac-
cording to Directive PED 2014/68/EU)
GWP (Global Warming Potential) = 1430.
!
In case of refrigerant leakage, ventilate the room.
6.3 Preventive Maintenance Programme
To guarantee lasting maximum dryer effi
ciency and reliability
Maintenance
Activity Description
Maintenance Interval
(standard operating conditions
)
Activity
Check
Service
Da
ily
W
eek
ly
4 M
on
ths
12 M
on
ths
Check POWER ON indicator is lit.
Check control panel indicators.
Check condensate drain.
Clean condenser fi ns.
Check electrical absorption.
Depressurize the dryer. Complete
drain maintenance.
Depressurize the dryer. Replace pre-
and post-fi lter elements.
Th
e following are available (see par. 8.4):
a) compressor kits;
b) fan kits;
c) automatic expansion valve kits;
d) individual spare parts.
6.4 Dismantling
Th
e refrigerant and the lubricating oil contained in the circuit must be
recovered in conformity with current local environmental regulations.
Th
e refrigerant fl uid is recovered before fi nal scrapping of the equipment
((EU) No. 517/2014 art.8).
%
Recycling Disposal
Z
structural work
steel/epoxy-polyester resins
exchanger
aluminium
pipes
aluminium/copper
drain
polyamide
exchanger insulation
EPS (sintered polystyrene)
pipe insulation
synthetic rubber
compressor
steel/copper/aluminium/oil
condenser
steel/copper/aluminium
refrigerant
R134a
valves
brass
electrical cables
copper/PVC
Summary of Contents for Starlette Plus
Page 2: ......
Page 64: ...E SPL040 060 6 6...
Page 70: ...SPL040 060 6 6...
Page 80: ...8 6 DIMENSIONAL DRAWING 10 SPL040 060 i n c h e s mm...
Page 81: ...8 7 REFRIGERANT CIRCUIT 11 SPL040 060 SPL 040 SPL 050 060...
Page 82: ...8 8 WIRING DIAGRAM 12 SPL040 060 SPL 040...
Page 83: ...8 8 WIRING DIAGRAM 13 SPL040 060 SPL 050...
Page 84: ...8 8 WIRING DIAGRAM 14 SPL040 060 SPL 060...
Page 99: ...RU 8 8 C M R www polewr com 2 o 1 a e Parker b Quasar LCD c d e f g 8 8 1 2 3 4 5 a b...
Page 100: ...13 196 2003...
Page 102: ...196 2003...
Page 104: ......
Page 105: ......