8.3 Technical data
4
SPL004-030
MODEL
Weight
Refrigerant
R134a (Kg)
MIN.- MAX
Ambient Temperature
Amb
Compressed
air inlet
Temperature
F.L.A.[A]
Minimum
section
validated
cable for
electrical
connection
Compressed
air inlet
air outlet
Connections
(tightenning
torque)
Sound
pressure
level
During
transport
and stockage
After
installation
(lb)
(Kg)
(oz)
(Kg)
(CO
2
)
In
115V
±10%
1ph/60Hz
230V ±10%
1ph/60Hz
Ø
NPT
[N x m]
[dB (A)]
-
41.8
19
5.99
0.17
0.24
32-122° F
0-50°C
41-122°F
5-50°C
149°F
65°C
3.74
-
3G16AWG
NPT
(compatible)
1/2
50
50
SPL004
SPL006
-
SPL009
51.8
23.5
9.52
0.27
0.39
4.78
-
55
SPL012
SPL018
58.4
26.5
8.81
0.25
0.36
8.31
-
NPT
(compatible)
3/4”
SPL024
68.3
31
9.52
0.35
0.50
10.23
-
SPL030
77.2
35
12.34
0.55
0.79
-
6.22
Calibration values
Expansion automatic valve
AEV
Air - Side Max. Working Pressure
Fan pressure Switch
12 PV
SPL004-006
35 PSIg (+ 1.5, - 0)
2.4 bar (+ 0.1, - 0)
232 PSIg
16bar
ON: 160 PSIg
OFF: 109 PSIg
ON: 11 bar
OFF: 7,5 bar
SPL009-030
32 PSIg (+ 1.5, - 0)
2.2 bar (+ 0.1, - 0)
Summary of Contents for SPL004
Page 2: ......
Page 15: ...1 SPL004 030 Appendice Ap ndice Appendix...
Page 20: ...8 5 Exploded drawing 6 SPL004 030 2 3 8 13 1 7 4 11 14 6 15 12 KA1 KT T01...
Page 21: ...8 6 Dimensional SPL004 006 7 SPL004 030 inches mm...
Page 22: ...8 6 Dimensional SPL009 012 8 SPL004 030 inches mm...
Page 23: ...8 6 Dimensional SPL018 030 9 SPL004 030 inches mm...
Page 24: ...8 7 Refrigerant circuit SPL004 030 10 SPL004 030...
Page 25: ...8 8 Wiring diagram SPL004 006 11 SPL004 030...
Page 26: ...Wiring diagram SPL009 030 12 SPL004 030...
Page 27: ...Wiring diagram optional free contact SPL030 13 SPL004 030...