background image

   

,

 .

1

       SPL004-030     

Appendice

 Apéndice

Appendix

 

Summary of Contents for SPL004

Page 1: ...Starlette Plus Date 03 01 2017 Rev 23 CODE 398H272864 SPL004 SPL006 SPL009 SPL012 SPL018 SPL024 SPL030 User manual Manuel d utilisation Manual de uso 60Hz Refrigeration Dryer...

Page 2: ......

Page 3: ...e for the correct or foreseeable use of the machine itself or its components IMPORTANT The manufacturer reserves the right to modify this manual at any time The most comprehensive and updated informat...

Page 4: ...ng distance 3 mm ahead of the system RCCB IDn 0 3A see the relevant current local regulations The nominal current In of the magnetic circuit breaker must be equal to the FLA with an intervention curve...

Page 5: ...ourless gas classified in SAFETY GROUP A1 EN378 group 2 fluid according to Directive PED 2014 68 EU GWP Global Warming Potential 1430 In case of refrigerant leakage ventilate the room 6 3 Preventive M...

Page 6: ...eek external as sistance Ice formation on evapo rator low evaporation pressure By pass air flow keep ing air inlet open Open condensate drain valve manually Restart appliance checking setting of expan...

Page 7: ...les dommages ou d g ts ventuels pouvant r sulter de manipulations malveillantes et ou de modifications de l emballage L utilisateur doit s assurer que les conditions fournies pour la s lection de l un...

Page 8: ...homologu aux sens des normes fran aises en mati re d lectricit et de la r glementation locale pour la section minimale du c ble voir paragraphe 8 3 Installer l interrupteur magn to thermique diff rent...

Page 9: ...ales est un gaz incolore appartenant au SAFETY GROUP A1 EN378 fluide groupe 2 selon la directive PED 2014 68 EU GWP Global Warming Potential 1430 En cas de fuite de r frig rant a rer le local 6 3 Prog...

Page 10: ...re dans l vaporateur basse pres sion d vaporation by passer l air en maintenant ouverte l arriv e d air Ouvrir manuellement l vacuation des condensats Remettre en marche en v rifiant le tarage de la s...

Page 11: ...ente previsible de la misma unidad o de los componentes ATENCI N El fabricante se reserva el derecho de modificar sin previo aviso la informaci n de este manual Para que la informa ci n resulte comple...

Page 12: ...consulte las disposiciones locales al respecto La corriente nominal In de dicho magnetot rmico debe ser igual a FLA y la curva di intervenci n de tipo D 3 5 Conexi n del drenaje de condensados El seca...

Page 13: ...N378 fluido del grupo 2 seg n la directiva PED 2014 68 EU GWP Global Warming Potential 1430 En caso de fuga de refrigerante airee el local 6 3 Programa de mantenimiento preventivo Per garantire nel te...

Page 14: ...icitar asistencia externa formaci n de hielo en el evaporador baja presi n de evaporaci n derivar el aire by pass dejando abierta la entrada de aire Abrir manualmente el drenaje de condensados Reactiv...

Page 15: ...1 SPL004 030 Appendice Ap ndice Appendix...

Page 16: ...de condensation Salida aire de condensaci n Condensation air outlet Entr e air de condensation Entrada aire de condensaci n Condensation air inlet 1 MC Compresseur Compresor Compressor 2 Condenseur r...

Page 17: ...eeding dryer design pressure Tuyaux flexibles pour raccordements de l air si le r seau est soumis des vibrations Tubos flexibles para las conexiones de aire si la red est expuesta a vibraciones Hoses...

Page 18: ...30V 10 1ph 60Hz NPT N x m dB A 41 8 19 5 99 0 17 0 24 32 122 F 0 50 C 41 122 F 5 50 C 149 F 65 C 3 74 3G16AWG NPT compatible 1 2 50 50 SPL004 SPL006 SPL009 51 8 23 5 9 52 0 27 0 39 4 78 55 SPL012 SPL0...

Page 19: ...quest On request On request 398H785241 On request Spare parts Refrigerant condenser 2 398H114800 398H114801 398H114802 398H114803 398H114804 Evaporator Separator Air air heat exchanger 4 398H472157 39...

Page 20: ...8 5 Exploded drawing 6 SPL004 030 2 3 8 13 1 7 4 11 14 6 15 12 KA1 KT T01...

Page 21: ...8 6 Dimensional SPL004 006 7 SPL004 030 inches mm...

Page 22: ...8 6 Dimensional SPL009 012 8 SPL004 030 inches mm...

Page 23: ...8 6 Dimensional SPL018 030 9 SPL004 030 inches mm...

Page 24: ...8 7 Refrigerant circuit SPL004 030 10 SPL004 030...

Page 25: ...8 8 Wiring diagram SPL004 006 11 SPL004 030...

Page 26: ...Wiring diagram SPL009 030 12 SPL004 030...

Page 27: ...Wiring diagram optional free contact SPL030 13 SPL004 030...

Page 28: ...e to adhere to this procedure will result in loss of warranty c Seller reserves the right to replace a product under warranty and will accept no costs as to the removal and installation of the product...

Page 29: ...e de la garantie c La soci t fournisseur se r serve le droit de remplacer un produit sous garantie et n acceptera aucun frais de retrait et d installation des produits d La soci t fournisseur se r ser...

Page 30: ...o y posteriormente enviado al Proveedor El incumplimiento de este procedimiento causar la invalidaci n de la garant a c El Proveedor se reserva el derecho a reemplazar un producto en garant a y no asu...

Page 31: ...Information Centre Free phone 00 800 27 27 5374 from AT BE CH CZ DE DK EE ES FI FR IE IL IS IT LU MT NL NO PL PT RU SE SK UK ZA US Product Information Centre Toll free number 1 800 27 27 537 www park...

Page 32: ...co MI Italy Sede Operativa Gas Separation and Filtration Division EMEA Strada Zona Industriale 4 35020 S Angelo di Piove PD Italy tel 39 049 971 2111 fax 39 049 9701911 Web site www parker com hzd e m...