Device description
PSUP Mains module
18
192-120147N9 PSUP Manual 2019-06
2.3.2.
Connections on the device bottom
Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
Caution!
When the control voltage is missing there is no indication whether or not high
voltage supply is available.
Attention - PE connection!
PE connection with 10mm
2
via a grounding screw at the bottom of the device.
Attention - hot surface!
The heat dissipater can reach very high temperatures (>70°C)
P
Mains module PSUP
X40
Ballast resistor
X41
Power supply
1
Central ground connection for the axis system,
with 10mm
2
to the ground screw on the housing.
4
Fan*
* is internally supplied.
Line cross-sections of the power connections
PSUP10
Mains supply: 0.5 ... 6 mm
2
(AWG: 20 ... 10)
Braking resistor: 0.25 ... 4 mm
2
(AWG: 23 ... 11)
PSUP20 & PSUP30
Mains supply: 0.5 ... 16 mm
2
(AWG: 20 ... 6)
Braking resistor: 0.25 ... 4 mm
2
(AWG: 23 ... 11)