192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07
09.10.19 09:27
35 (109)
Data of the integrated braking resistor PSD1-S
Category
Specifications
Device
Maximum current
Max. Duty Cycle
Minimum
resistance value
Peak
Duration
PSD1-SW1200
PSD1-SW1300
7.84 A
0.1 A
1.27% @ 60 s
51
Ω
(40W)
External ballast resistors from Parker (see page
4.8
X52: Motor connection (PSD1-S)
Pin Designation
Motor cable lead designation*
1
U
U / L1
1
U1
2
V
V / L2
2
U2
3 W
W / L3
3
U3
4
FE & PE
YE / GN
* Depending on cable type.
FE: Functional ground
PE: Protective earth
Shielding connection of
the motor cable
The outer shielding of the motor cable must be correctly connected to PE both on
the
drive side
(see page 46, see page 59, see page 30) as well as on the motor
side. Shielding may not be interrupted.
Please observe the notes in chapter “
Operating conditions for CE-conform
operation
(see page 13)“.
4.8.1.
Motor connection with self-made motor cable
Please consider special features of the
DSL
motor connection with:
•
EX motors,
•
EY motors,
•
NK motors,
•
NV motors and
•
NX motors!
With
these motors with DSL feedback, the outputs U & V are reversed in the PSD
via the motor configuration
This has no effect on the wiring with Parker motor cables,
you can connect them as shown in the table.
For EX motors, EY motors, NK motors, NV motors and NX motors:
Pin Designation
Motor cable lead
designation*
Motor side:
EX, EY, NK, NV, NX
1
U
U / L1
1
U1
U
2
V
V / L2
2
U2
W
3
W
W / L3
3
U3
V
4
FE & PE
YE / GN