Mains connection Power module PSD1-M_P010 with line choke
Increased power by means of a line choke
Category
Specifications
PSD1-M_P010 with line
choke
230 V
400 V
480 V
Mains voltage
230 VAC ±10 % 50-60 Hz
400 VAC ±10 % 50-60 Hz
480VAC ±10% 50-60Hz
Rated voltage
3 AC 230 V
3 AC 400 V
3 AC 480 V
Input Current
24.5 A
24.5 A
20.4 A
Output voltage
325 VDC ±10 %
565 VDC ±10 %
680 VDC ±10 %
Output power
9 kW
15 kW
15 kW
Pulse power (<5 s)
18 kW
30 kW
30 kW
Power dissipation
70 W
70 W
70 W
Maximum fuse rating per
device
Measure for line and device protection:
UL listing (DIVQ) automatic circuit breaker
Manufacturer: ABB, Stotz-Kontakt GmbH (E212323)
Model No.: S203UP-K, 1 automatic circuit breaker
480 VAC, 3-phase, 25 A, Operating temperature 55 °C
Earth leakage current
Current on the mains PE (>3,5 mA)
Supply networks
Possible supply networks: TN
The specified performance data are only valid in connection with line choke
IND-0001-02.
7.3
Mains Connection Power module PSD1-M_P020 without line
choke
Category
Specifications
PSD1-M_P020
230 V
400 V
480 V
Mains voltage
230 VAC ±10 % 50-60 Hz
400 VAC ±10 % 50-60 Hz
480VAC ±10% 50-60Hz
Rated voltage
3 AC 230 V
3 AC 400 V
3 AC 480 V
Input Current
44 Arms
44 Arms
35 Arms
Output voltage
325 VDC ±10 %
565 VDC ±10 %
680 VDC ±10 %
Output power
12 kW
20 kW
20 kW
Pulse power (<5 s)
24 kW
40 kW
40 kW
Power dissipation
120 W
120 W
120 W
Maximum fuse rating per
device
2 fuses in line are required
Measure for line protection:
MCB (K characteristic) with a rating of 50A / 4xxVAC (depending on the input
voltage)Recommendation:
Recommendation: (ABB) S203U-K50 (440VAC)
Measure for device protection:
Fuses 80A / 700VAC per supply leg in accordance with UL category JFHR2: