Earthing of all other PSD1M devices:

 

The earth connection of the motor (and feedback) cable(s) is carried out using 

the supplied tin angles: 

 

 

Mounting: 

 

Fix cables with clamp collars on the 

corresponding tin bar (3) 

 

Connect plug 

 

Screw on tin angle 

 

remarks 

Fixing screw for tin angle (included 

with delivery) 

Tin angle for cable guiding with 

earthing screw 

Mounting of cable, and flat 

shielding 

Central ground connection 

 

 

Tin angles and clamp collars are all 

included. 

 

Alternatively, the earth connection of the motor shielding is also possible via the 

rear wall of the control cabinet or a PE bus bar: 

 

 

Summary of Contents for PSD1-S

Page 1: ...192 011003N7_PSD1 M_Short_Description 1 31 192 011003N7 DOC 0001 01 B 11 12 23 11 39 192 011003N7 DOC 0001 01 B 2023 11 Up from release 1 11 1 PSD1 M Parker Servo Drive Quick guide...

Page 2: ...h Strasse 22 77656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail EMPD IndControlDrivesTech support parker com mailto EMPD IndCont...

Page 3: ...f utilization for the cUL certification of PSD1 S 13 4 Plug and device overview PSD1 M 14 4 1 Front view PSD1 M 15 4 2 View from below PSD1 M 16 4 3 View from above PSD1 M 18 4 4 Signal interfaces IO...

Page 4: ...where to find it Software Tool Field Bus Files CE declaration of compliance PSD ServoManager Downloads under http solutions parker com psd_support Description of the product In addition to the short...

Page 5: ...8 A PSD1 M_1600 15 A PSD1 M_1800 30A PSD1 M_2220 2 A 2 A PSD1 M_2330 5 A 5 A PSD1 M_2440 8 A 8 A PSD1 M_2630 15 A 5 A PSD1 M_3222 2 A 2 A 2 A PSD1 M_3433 8 A 5 A 5 A PSD1 MWP010 Mains module 10 kW PSD...

Page 6: ...injuries or material damages The device might be destroyed what could result in fire The device corresponds to EN 61800 3 i e it is subject to limited sale The device can emit disturbances in certain...

Page 7: ...mental protection act Disposal via a technical waste dump which is allowed to take on electrolytic aluminium condensers Do under no circumstances dump the circuit boards at a place near a normal waste...

Page 8: ...programming modifying the conditions of utilization and operating modes and to maintenance work This manual and the help information must be available close to the device during the performance of al...

Page 9: ...and in an axis system only in a defined original state If the axis controller is replaced it is absolutely necessary to transfer the configuration determining the correct operation of the drive to th...

Page 10: ...hin the drive and system for loose ends blends grinding or drilling chips etc Check all external power circuits of the system Power supply control motor and ground connections Make sure no damages or...

Page 11: ...lease respect the specifications of the manual resp of the help function especially the technical characteristics mains connection circuit breakers output data ambient conditions 3 1 2 Mains filter fo...

Page 12: ...tor holding brake must not be interrupted 3 1 7 Cable installation Signal lines and power lines should be installed as far apart as possible cross points 90 Signal lines should never pass close to exc...

Page 13: ...N 61800 3 This product can cause high frequency disturbance in domestic areas Users are asked to take suitable action if this proves to be the case 3 2 CE declaration of conformity PSD1 M CE declarati...

Page 14: ...M 14 31 192 011003N7 DOC 0001 01 B 11 12 23 11 39 In this chapter you can read about Front view PSD1 M 15 View from below PSD1 M 16 View from above PSD1 M 18 Signal interfaces IO Optionboard 19 4 Plu...

Page 15: ...nputs and Encoderinput IO Optionboard2 S12 Device address higher value half byte accept with power ON S13 Device address low value half byte accept with power ON P14 Status LED axis 1 P15 Status LED a...

Page 16: ...mperature sensor Axis 1 3 depending on the device Front view see page 15 Shows pin 1 of the connector Earthing PSD1M_1800 Explanation 1 DSL connection 2 Connection of motor brake 3 Connect ground via...

Page 17: ...es with clamp collars on the corresponding tin bar 3 Connect plug Screw on tin angle remarks 1 Fixing screw for tin angle included with delivery 2 Tin angle for cable guiding with earthing screw 3 Mou...

Page 18: ...31 192 011003N7 DOC 0001 01 B 11 12 23 11 39 4 3 View from above PSD1 M Front view see page 15 X60 PC Interface to configure and program servo axes X61 Fieldbus Interface output X62 Fieldbus Interface...

Page 19: ...tputs 24V power supply Pin X30 X37 1 24VDC external 24V for digital outputs 2 GND GND24V 3 Digital I O0 combined inputs outputs When the outputs is set the High signal is read also at the input The ou...

Page 20: ...in 1 Iin1 analog Input 0 20mA 5 Vcc 5V Output Power Supply for Encoder max 150mA 6 RS422 A A Encoder In Out Step Encoder In Out 7 RS422 A A Encoder In Out Step Encoder In Out 8 RS422 B B Encoder In Ou...

Page 21: ...wiring or loosening electrical connections please observe the following Risk of electric shock disconnect power before removing cover resp disconnect the devices from the mains supply Caution Dangero...

Page 22: ...1 192 011003N7 DOC 0001 01 B 11 12 23 11 39 5 2 View from below PSD1 M_P mains module Front view see page 21 X40 Ballast resistor X41 Power supply Central ground connection Connect ground via ring cab...

Page 23: ...ve the device at least 100 mm in order to ensure free circulation of the cooling air Please do also respect the recommended distances of other devices Make sure that the mounting plate is not exhibite...

Page 24: ...t dissipator Mounting spacing At the top and below at least 100mm Information on PSD1 M Size 1 Multi axes servo drives and Mains Module PSD1 M_P010 Mounting 2 socket head screws M6 Lateral distance of...

Page 25: ...9 25 31 6 2 Mounting and dimensions PSD1 M size 2 Information on PSD1 M Size 2 Multi axis Servo Drives 30 A and Mains Module PSD1 M_P020 Required mounting distance for heat regulation at the top and b...

Page 26: ...ction Power module PSD1 M_P010 without line choke Category Specifications PSD1 M_P010 230 V 400 V 480 V Mains voltage 230 VAC 10 50 60 Hz 400 VAC 10 50 60 Hz 480VAC 10 50 60Hz Rated voltage 3 AC 230 V...

Page 27: ...ng temperature 55 C Earth leakage current Current on the mains PE 3 5 mA Supply networks Possible supply networks TN The specified performance data are only valid in connection with line choke IND 000...

Page 28: ...ussmann 170M1366 or 170M1566D Earth leakage current Current on the mains PE 3 5 mA Supply networks Possible supply networks TN The specified performance data are only valid in connection with line cho...

Page 29: ...ategory Specifications Controller type Weight kg Dimensions Height x Width x Depth mm PSD1 M_1300 4 360 x 50 x 270 PSD1 M_1500 PSD1 M_1600 PSD1 M_P010 PSD1 M_2220 4 PSD1 M_2330 PSD1 M_2440 PSD1 M_2630...

Page 30: ...odule PSD1 M_P020 with line choke 28 Mains Connection Power module PSD1 M_P020 without line choke 27 Mains filter for use in industrial areas 11 Motor and feedback cable requirements 12 Motors 12 Moun...

Page 31: ...192 011003N7_PSD1 M_Short_Description 192 011003N7 DOC 0001 01 B 11 12 23 11 39 31 31...

Reviews: