Chapter 3: Starting Your PowerStation
PowerStation Connectors
PA2 PowerStation User Guide
3-3
Caution: Note that RTS and CTS signals are not active in RS-422 and RS-
485 configurations.
Once you make a cable for communicating with COM2, you will need to set
the COM2 DIP switch settings.
COM2 is set to the RS-485 protocol by default. To change COM2 to the RS-
232 or RS-422 protocol, you must change the COM2 DIP switch settings.
The DIP switch for COM2 is located on the side of the PA2 PowerStation, as
shown in Figure 3-1.
Figure 3-1:
COM2 Dip Switch Settings
•
The white boxes represent the tip of the switch.
•
The upper half of the switch is the ON position, and the lower half of the
switch is the OFF position.
To change the DIP switch settings, complete the following steps:
1
Choose the appropriate DIP switch settings from the diagram
displayed on the side of the PA2 PowerStation and the chart below.
5
Signal ground
Signal ground
Signal ground
6
N/C
N/C
N/C
7
RTS, request to send
N/C
N/C
8
CTS, clear to send
N/C
N/C
9
N/C
N/C
N/C