Chapter 2: Installing the PowerStation
Installing an Optional AC Power Supply
PA2 PowerStation User Guide
2-11
3
Attach the ferrite to the section of the cord closest to the loose wires.
The ferrite is located in the PA2 mounting kit.
Connecting the Power Supply to the Workstation
Once you have mounted the power supply, you are ready to connect it to
the workstation.
1
Slide the positive and negative wires into the appropriate slots on the
power connector that was shipped with the workstation. See Figure
2-5.
Figure 2-5: Power Connector and Positive/Negative Wires
2
Connect the ground cable from the power connector to an earth
ground.
3
Connect the power cord from the power supply to an AC power
source.
4
Attach the power connector that you prepared in Step 1, to the
workstation.
You have successfully connected the power supply to your workstation.
You can now operate the workstation using AC power.
Caution:
All
PA2 PowerStation models can use 24 volt input DC power.
The PA200V and PA206 PowerStation models can use 12 or 24
volt input DC power. DO NOT connect AC power to the unit.
Power Connector
Power /- Wires