26
Electronics for Closed Loop Control
Series PID00A-40X
Operation Manual
PID00A_10 5715-616 UK.indd CM 14.11.14
Parker Hannifin Corporation
Hydraulics Group
Parameter overview for expert mode
Parameter
Description
Unit
Parameter range
Default setting
from
up to
P1
zero
%
-100.0
+100.0
0.0
P13
bypass gain
%
0
100.0
0
P14
T-portion PT1-element
–
0
100.0
0
P16
P-portion
–
0
100.0
0
P17
I-portion
–
0
100.0
0
P18
D-portion
–
-100.0
+100.0
0
P19
T-portion DT1-element
–
0
100.0
0
P21
comparator function window
%
0
200.0
0
P23
comparator rise delay time
ms
0
10000
0
P24
comparator turn-off
delay time
ms
0
10000
0
P26
window I-portion
%
0
20
20
P27
reduct. window I-portion
–
0
100.0
100.0
P28
T-portion PT1-filter
–
0
100.0
0
E25
MIN operating threshold
–
0 = 1%
0 = 1%
1 = 0.01%
E50
average quantity
–
1
10
1
E70
velocity feedback
–
0 = inactive
0 = inactive
1 = active
E71
MIN position
%
-120.0
+120.0
-120.0
E72
MAX position
%
-120.0
+120.0
+120.0
E73
sensor length
mm
1
10000
10000
E74
MAX velocity
mm/s
1
10000
10000
E75
set value output function
–
0 = y=X (synchronous)
0 = y=x
1 = y=1-x (reversal)
E79
MIN fadeout position
%
-120.0
+120.0
-120.0
E80
MAX fadeout position
%
-120.0
+120.0
+120.0
Summary of Contents for PID00A-40 Series