Electronics for Closed Loop Control
Series PID00A-40X
Operation Manual
PID00A_10 5715-616 UK.indd CM 14.11.14
Parker Hannifin Corporation
Hydraulics Group
Individual description of basic parameters
S5
ramp accel. A
Adjustment of ramp rate for increasing of positive polarity signal.
To avoid switching noise.
S6
ramp decel. A
Adjustment of ramp rate for decreasing of positive polarity signal.
To avoid switching noise.
S7
ramp accel. B
Adjustment of ramp rate for increasing of negative polarity signal.
To avoid switching noise.
S8
ramp decel. B
Adjustment of ramp rate for decreasing of negative polarity signal.
To avoid switching noise.
S18
fade out ramp
Adjustment of ramp rate for position dependent decreasing of signal.
To automate motion sequences.
P3
MAX A
Adjustment of maximum signal span for positive polarity output signal.
To match the command signal span to the drive operating range.
P4
MAX B
Adjustment of maximum signal span for negative polarity output signal.
To match the command signal span to the drive operating range.
P7
MIN A
Adjustment of positive polarity signal step.
To compensate for the overlap of the valve spool.
P8
MIN B
Adjustment of negative polarity signal step.
To compensate for the overlap of the valve spool.
P11
command signal polarity
Adjustment of the command signal polarity.
To match the command signal polarity to the control path.
P12
feedback signal polarity
Adjustment of the feedback signal polarity.
To match the sensor signal polarity to the control path.
P20
feedback scale
Adjustment of the feedback scaling.
To match the drive operating range to the feedback input signal span.
P29
polarity set value
Adjustment of the set value signal polarity.
To match the set value signal polarity to the control path.
E2
closed loop control
Adjustment of the operating mode for the controller.
To select the control function.
E11
type of feedback device
Adjustment of the feedback device type.
To match the feedback input to the signal device features.
E12
cable break detection
feedback
Adjustment of the operating mode for the feedback cable break detection.
To turn on resp. off of the cable break detection for the feedback signal.
E17
type of command signal
device
Adjustment of the command signal option.
To match the command signal input to the input signal mode.
E19
cable break detection
command
Adjustment of the operating mode for the command cable break detection.
To turn on resp. off of the cable break detection for the command signal
at a selected command signal option of 4...20mA..