14
Electronics for Closed Loop Control
Series PID00A-40X
Operation Manual
PID00A_10 5715-616 UK.indd CM 14.11.14
Parker Hannifin Corporation
Hydraulics Group
Connection of an inappropriate sensor may
lead to permanent damage to the electronics
module.
put signal processing are available, which are de-
scribed below.
The output signal option has to be selected
according to the requirements of the down-
streamed electronic (parameter E20).
Signal output:
The terminals 7 and 9 provides the output signal
(set value), which may be used to control exter-
nal amplifier modules, integrated valve amplifiers
as well as servo valves. Different versions of out-
Wiring diagram of voltage 10...0...-10V
Wiring diagram of current 20...0...-20mA
Wiring diagram of current 4...12...20mA
Sensor input
The sensor has to be wired to the terminals 13 and
16, the earth ground connection will be made via ter-
minal 8. The connection has to be shielded. The sen-
sor type is selectable via software parameter E11.