User Guide
21
Inputs
3.4.1. Low power, high-side output capabilities
The following table provides specifications for the inputs when used as low power
outputs.
Low Power Output Specifications
Item
Min
Nom
Max
Unit
Operational voltage range
9
32
V
Output resistance w.r.t. GND (output off)
26.2
k
Output voltage
4.3
5.0
V
Output current
358
mA
Leakage current (output off)
1
µA
Output pin capacitance
10
nF
3.4.1.1. Low power, high-side output connections
You must be aware of the following when connecting the low power, high-side
outputs:
▪
the outputs are connected to the in5 Vdc supply through a pull-up
resistor. Each output is de-rated to 4.3 V. Maximum load on each output is
358 mA.
▪
the outputs can provide power to LED or other small loads in a vehicle.
When connecting the low power, high-side outputs, ensure you follow these best
practices:
▪
the outputs should not be connected to loads that will draw currents greater
than the maximum current.
▪
The grounds for the loads should be connected physically close to the PHD
power grounds.
Summary of Contents for PHD28
Page 1: ...Parker Hannifin Display PHD User Guide UG PHD 1040001 201707 010...
Page 52: ...44 PHD Mounting the PHD 9 1 2 PHD50 Figure 18 PHD50 dimensions mm...
Page 53: ...User Guide 45 Mounting the PHD 9 1 3 PHD70 Figure 19 PHD70 dimensions mm...
Page 58: ...Parker Hannifin Display PHD User Guide HY33 5021 IB US...
Page 59: ...PHD Network Interface Configuration Publ no HY33 5021 M1 UK Edition 2017 02 02...
Page 75: ...PHD API Reference Publ no HY33 5021 M2 UK Edition 2017 02 13...