12
PHD
Inputs
The PHD has digital, frequency, and analog inputs.
Damage to equipment!
Do not connect inputs directly to unprotected
inductive loads such as solenoids or relay coils, as these can produce
high voltage spikes that may damage the PHD. If an inductive load must
be connected to an input, use a protective diode or transorb.
3.1. PHD28 inputs
The PHD28 has up to 7 analog inputs:
▪
GPIO1
through
GPIO7
Analog inputs are typically used to read electrical signals that span a voltage
range.
Analog inputs
GPIO1
through
GPIO7
can also be configured as digital inputs with
wake-up functionality.
Additionally, all inputs can be configured as high-side, low voltage/low current
outputs.
The different configurations are done in software.
3. Inputs