EN
21
6 Troubleshooting
In the unlikely event that a problem occurs on the equipment, this troubleshooting guide can be used to identify the probable cause and remedy.
Troubleshooting should only be attempted by competent personnel. All major repair, and calibration work should be
undertaken by a Parker domnick hunter trained, qualified and approved engineer.
Fault
Probable Cause
Remedy
Power Connected but LCD and status
indicators not illuminated.
Fuse Blown
Replace Fuse
Ribbon cable disconnected
Reconnect Ribbon cable
Power disconnected
Reconnect Power
No / Low gas outlet pressure
Service Overdue
Service the generator
Internal gas leak
Check and Rectify
External gas leak
Check and Rectify
Low inlet pressure
Ensure pressure meets required specification
High Oxygen concentration.
Defective Oxygen cell.
Replace.
Leak in system piping.
Check and Rectify
Low inlet pressure
Compressor or ring main pressure low.
Check and Rectify
Inlet valve not open
Check and Rectify
Defect on pre-treatment package.
Refer to pre-treatment manual.
Excessive noise or vibration
Silencer loose or defective.
Check and Rectify
Solenoid valve wear or coil loose.
Check and replace if required.
High outlet pressure.
Outlet regulator defective.
Reset or replace.
Summary of Contents for MAXIGAS MX104