Installation and servicing manual
Air Oil Coolers, LOC
20
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY10-6003-UM/EU
Technical specification
Technical specification
Cooling system
Maximum working pressure
10 bar
Heat transfer tolerance:
± 6 %
Maximum permitted oil temperature
100 °C
Compatibility
Mineral oil
Synthetic oils
Vegetable oils
For use with other oils or operation in extreme conditions,
contact your local Parker office.
Material
Pump housing/Cooler matrix
Aluminium
Filter unit (option)
Aluminium
Fan housing
Steel
Fan blades/hub
Glass fiber reinforced polypropylene/aluminium
Fan guard
Steel
Surface treatment
Electrostatic powder coating
Electric motor
3-phase asyncronuous motor according to
IEC 60034-1
Recommended surrounding temperature
-20 °C - +40 °C
Insulation standard
F
Rise in temperature
B
Protection standard
IP 55
Regarding nominal voltage, see separate eletric motor manual.