Object list
COMPAX CANopen
Synchronization window length
12
6.2.6 Synchronization window length
The synchronization window length is the period between the arrival of the SYNC message and the last
synchronous PDO which was thereby triggered in µs.
It is 0 when it is not in use.
COMPAX does not support this function.
Object Description
Index
0x1007
Standard
0x00000000
Length
4
Min
0x00000000
Object code
Variable
Elements
Max
0xFFFFFFFF
Data type
Unsigned32
Access rights
read/write
PDO mapping
no
Data Description
Unit
µs
6.2.7 Device name
This object contains the device name.
Object Description
Index
0x1008
Standard
COMPAX
Length
Min
Object code
Elements
Max
Data type
Visible string
Access rights
constant
PDO mapping
no
6.2.8 Hardware version
This object contains the device hardware version.
Object Description
Index
0x1009
Standard
CPX 3.0
Length
Min
Object code
Elements
Max
Data type
Visible string
Access rights
constant
PDO mapping
no
6.2.9 Software version
This object contains the device software version.
Object Description
Index
0x100A
Standard
1.00
Length
Min
Object code
Elements
Max
Data type
Visible string
Access rights
constant
PDO mapping
no