Parker EME
Error
I11 T11 192-120101 N6 - March 2004
95
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Reduce the number of or the nesting depth of function module instances
Note:
Stack overflow in the IEC runtime caused by too many function module
entities. Execution is aborted at this point and the cycle is restarted after the
selected cycle time.
Error code (hex):
0x6284
Error:
IEC61131-3 Invalid command
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Recompile the program / download and verify the compiler version
Note:
Invalid opcode in the IEC program Execution is aborted at this point and the
cycle is restarted after the selected cycle time.
Error code (hex):
0x7121
Error:
Motor stalled
Error reaction:
Reaction 5: deenergize immediately (without ramps), apply brake.
Measure:
Note:
Speed controller signal at limit for specific time
Error code (hex):
0x7180
Error:
Motor impulse current monitoring
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Adjustable monitoring (with motor parameters: pulse current time and pulse
current)
The current value can be read with the "Motor impulse utilization" status
display.
An error message is generated for a motor impulse utilization of 115%.
Error code (hex):
0x7310
Error:
Rotation speed too high
Error reaction:
Reaction 5: deenergize immediately (without ramps), apply brake.
Measure:
Note:
Rotation speed too high
Error code (hex):
0x7320
Error:
Tracking error
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Monitoring of tracking error window incl. time
Error code (hex):
0x7381
Error:
Resolver level too high
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Check feedback cable or feedback
Note: The feedback excitation voltage is deactivated for level errors!
Note:
Level limit exceeded, can only be reset by powering on the device again.
Error code (hex):
0x7382
Error:
Resolver level too low
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Check feedback cable or feedback
Note: The feedback excitation voltage is deactivated for level errors!
Note:
Level has fallen below limit, can only be reset by powering on the device
again.
Error code (hex):
0x7391
Error:
Encoder level too high
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Check feedback cable (shield, abort, short-circuit) or feedback
Note: The feedback power supply voltage is deactivated for F11!
Note:
SinCos feedback/encoder: Level of Sine/Cosine trace too high, can only be
reset by powering on the device again. The limit for Firmware >V2.x.x is at
the physical limit 2.5Vss.
Error code (hex):
0x7392
Error:
Encoder level too low
0x6284
0x7121
0x7180
0x7310
0x7320
0x7381
0x7382
0x7391
0x7392