Error
104
I11 T11 192-120101 N6 - March 2004
Error code (hex):
0xFFE1
Error:
CamOut not possible during coupling process
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
PLCopen function module CamOut cannot be called during coupling
process.
Note:
Error in the IEC61131-3 program sequence. PLCopen function module
CamOut was called even though the axis was not yet coupled.
Error code (hex):
0xFFE2
Error:
Invalid parameter transfer while calling a function module.
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Call PLCopen function module with matching parameters.
Note:
Error in the IEC61131-3 program sequence. Function module was called
with incorrect parameters.
Error code (hex):
0xFFE3
Error:
Coupling // decoupling only possible with C3_CamIN or C3_CamOut Mode
0
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Coupling with a linear actuator only possible with Mode 0.
Note:
Error in the IEC61131-3 program sequence. An attempt was made with a
linear actuator to couple with another mode than 0.
0xFFE1
0xFFE2
0xFFE3