10)
High Pressure Pump and Motor Assembly (Included)
: The High-Pressure Pump Assembly provides high
pressure to the vessel membranes to produce potable water.
Figure 2.22: High Pressure Pump and Motor Assembly
High Pressure Pumps:
SINGLE/THREE
PHASE
PERMEATE GPD
VOLTAGE
HIGH PRESSURE
PUMP PART
NUMBER
SINGLE/THREE
PHASE
SINGLE
2800 - 3600 GPD
110/230 AC/50/60 Hz
B016080026
SINGLE
THREE PHASE
2800 - 3600 GPD
208/460 AC/50/60 Hz
B016080027
THREE PHASE
SINGLE
4400 - 6200 GPD
115/230 AC/50/60 Hz
B016600005
SINGLE
THREE PHASE
4400 - 6200 GPD
380/460 AC/50/60 Hz
B016510001
THREE PHASE
SINGLE
2800 - 3600 GPD
110/230 AC/50/60 Hz
B016080026
SINGLE
Table 2.3: High Pressure Pump and Motor Assembly
11)
Manifold Assembly:
The manifold connects all the necessary plumbing and displays the instrumentation for
the system.
The low-pressure and high-pressure transducers for the systems are directly connected to the manifold,
they make sure the system operate at safe conditions and are needed for the controller to operate.
The Flowmeter valve controls the product flow of the system, this also directly affects the pressure. The
flowmeter valve is used to incrementally adjust the unit pressure during the initial setup or maintenance of
the system.
Summary of Contents for AQUA DUO - A455C
Page 15: ...15 Figure 2 4 Piping and Instrumentation Diagram 2800 3600 GPD...
Page 17: ...17 Figure 2 6 Piping and Instrumentation Diagram 4800 6200 GPD...
Page 33: ...33 Figure 2 28 Hose Tube Connection Instructions Figure 2 29 Tubing Fitting Internals...
Page 64: ...64 8 DRAWINGS DIAGRAMS...
Page 65: ...65 1 P ID...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69 2 GA Drawing...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...
Page 73: ...73...
Page 74: ...74...
Page 77: ...77 4 Wiring Diagrams...
Page 78: ...78...
Page 79: ...79...
Page 80: ...80...
Page 81: ...81...