4.5.2 Optional Exhaust Vent Installation
Parker Hannifin offers the option to vent the exhaust heat away from the generator using the Exhaust
Vent Kit (part #B06-0394).
To install:
1. Screw the six cap screws into the threaded holes around the generator’s vent using the supplied
5/32” hex key. Screws will stand out from the surface of the sheetmetal.
2. Install the exhaust vent by placing it over the screws and sliding down until it is fully seated.
3. Secure the ducting using the supplied clamps. Route to the desired exhaust location.
For duct lengths above 15 ft, use of the Exhaust Vent Booster Fan (part #B06-0398) with the Exhaust
Vent Duct Extension (part #B04-0693) is required.
Reference Figures 13 & 14 for clarification on installation of the Exhaust Vent Kit and a depiction of how
to assemble the Exhaust Vent Booster Fan and Duct Extension.