background image

890 

Quickstart 

Manual 

 

890CS/CD (Common Bus) Drives 

Frames B, C & D with STO SIL3/PLe 

 

 

HA501027U000  Issue 1 

 

 

 

©

 Copyright 2010 Parker Hannifin Ltd. 

All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any 
form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives 
Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although 

every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to 
make amendments or correct omissions. Parker Hannifin Ltd., Automation Group, SSD Drives Europe cannot 

accept responsibility for damage, injury, or expenses resulting there from.

 

Summary of Contents for 890CS

Page 1: ...means to persons not employed by a Parker Hannifin Ltd Automation Group SSD Drives Europe without written permission from Parker Hannifin Ltd Automation Group SSD Drives Europe Although every effort h...

Page 2: ...D Feedback Connections 15 Drive Start up 16 Before Applying Power 16 Powering up the 890CS 17 Powering up each 890CD 17 890CD Set up 17 Motor Data 17 Quick Setup Parameters 18 Autotune 18 Running in L...

Page 3: ...after removal of the mains supply Wait for at least 3 minutes for the dc link terminals DC and DC to discharge to safe voltage levels 50V Measure the DC and DC terminal voltage with a meter to confirm...

Page 4: ...safety warnings therein must be observed Accessibility All live power terminals are IP20 rated only since the equipment is intended to be installed within a normally closed cubicle or enclosure which...

Page 5: ...he 890 is a system product and we have no knowledge of your application we detail the quickest way to power up the drive using a simple earthing scheme with minimal control wiring Refer to the full En...

Page 6: ...me it is very convenient to assemble drives of varying frame sizes into one common bus system Typically they are installed side by side SSD_Rail is an innovative busbar system that connects the DC and...

Page 7: ...he 890 Installation Kit is shown in the diagram attached to the bottom of the 890CD units It can also be fixed to the top of the unit The kit provides several options for earth ground connections It a...

Page 8: ...current draw on the DC busbar will exceed 140A Connect to the left and right busbar terminals separately The busbar is rated for operation at 140A Do not exceed 140A Ventilation The drives can be moun...

Page 9: ...Page 9 Overview...

Page 10: ...e braking terminals 3 Connect 3 phase power in any order to L1 L2 L3 Maximum wire sizes Frame B1 10mm2 8AWG Frame B2 16mm2 4AWG Frame D1 50mm2 1 0AWG Frame D2 95mm2 4 0AWG A 3 line reactor MUST be fit...

Page 11: ...s 4 Connect the earth ground wire to the bottom ground bracket Maximum wire sizes Frame B 4mm2 12AWG Frame C 10mm2 8AWG Frame D 16mm2 4AWG 5 Connect motor thermal switch or thermistor to Th1 Th2 Drive...

Page 12: ...o BC465938U200 200mm length The bus bar is rated at 140 Amps Busbar Installation 1 Simply select two correct lengths of the busbars and drop them in the slots shown in the close up top view Secure wit...

Page 13: ...This MUST be set to the incoming line voltage A Voltage Selection Connect a 24VDC power supply across terminals X01 01 and X01 04 mandatory 24VDC in terminal X01 01 0VDC in terminal X01 04 Run 24VDC p...

Page 14: ...1 Connect the shield to earth ground at the bottom ground bracket A Speed Reference OR External 2 wire speed reference between terminals X12 01 and X12 04 Connect the shield to earth ground at the bot...

Page 15: ...to match the encoder direction to the motor direction When TRUE changes the sign of the measured speed and the direction of the position count It is necessary to set up this parameter when in CLOSED L...

Page 16: ...d setpoints are all at zero Ensure that nobody is working on another part of the system which will be affected by powering up Ensure that other equipment will not be adversely affected by powering up...

Page 17: ...time 8 At this stage apply 3 phase power to the 890CS Changing ENABLE to high 24V OUT will cause the 890CS to power up the SSD_Rail 9 Pressing the STOP key on each 890CD will clear the DCLO trip Norm...

Page 18: ...a Stationary Autotune NOTE Some of the parameters are product code dependent that is they are different for each frame size and power rating For example the unit will be set for either 50Hz or 60Hz op...

Page 19: ...ored during power down Running in Remote On the 890CD keypad select REMOTE mode The display will show the remote Setpoint The value displayed depends on the external speed reference Dial in a speed se...

Page 20: ...n before you can change between local and remote modes Mode Action Hold the Stop key down until is displayed Remote to Local Hold the Stop key down until and are removed Local to Remote Displays the u...

Page 21: ...rsion of the unit From the Welcome Screen the display times out alternatively you can press the key to show the first of 5 diagnostics Output Power As a percentage of nominal full power for the select...

Page 22: ...h the parameters using the and keys Press to select a parameter for editing Increment decrement the parameter value using the and keys Press to exit the parameter This is the power up welcome screen I...

Page 23: ...ext parameter Edit stop editing show PREF hold increment value decrement value SEQ and REF LEDs are On when in Local mode To change Operating Mode From power up the keypad displays the Software Versio...

Page 24: ...QUICK SETUP menu at level 1 SETUP menu at level 1 SYSTEM menu at level 1 AC MOTOR DRIVE 15kW 400V 1 x DOWN arrow to get to the SETUP menu contains all the parameters DOWN arrow to get to the SYSTEM m...

Page 25: ...w the first of 5 diagnostics Output Power As a percentage of nominal full power for the selected input voltage Heatsink Temp The heatsink temperature in Centigrade Supply Frequency The real time frequ...

Page 26: ...C Analog and Digital I O 890CD Control Connections The terminal function names apply to the factory shipping configuration These terminals may have different functions if the configuration has been mo...

Page 27: ...Page 27 890CD Control Terminals...

Page 28: ...Page 28 890SD Control Terminals...

Page 29: ...Page 29 890CS Control Terminals...

Page 30: ...Page 30 Appendix D Electrical Ratings 890CS Common Bus Supply...

Page 31: ...Page 31 890CD Common Bus Drive...