Summary of Contents for 890 Series

Page 1: ...s G H J HA471391U000 Issue 6 aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding The full Product Manual is available on l...

Page 2: ...itted in any form or by any means to persons not employed by a Parker Hannifin Manufacturing Ltd without written permission from Parker Hannifin Manufacturing Ltd Although every effort has been taken...

Page 3: ...Page 2...

Page 4: ...13 890SD Feedback Connections 14 Drive Start up 15 Before Applying Power 15 Drive Set up 16 Motor Data 16 Quick Setup Parameters 16 Autotune 17 Running in Local 18 Running in Remote 18 Appendix A Usin...

Page 5: ...nal voltage sources mains suppy or otherwise to any of the braking terminals DC DBR Application Risk The specifications processes and circuitry described herein are for guidance only and may need to b...

Page 6: ...sulation All control and signal terminals are SELV i e protected by double insulation Ensure all wiring is rated for the highest system voltage NOTE Thermal sensors contained within the motor must be...

Page 7: ...rocedure Show you how to Autotune the drive and start the motor Because the 890 is a system product and we have no knowledge of your application we detail the quickest way to power up the drive using...

Page 8: ...on Negative DC Buss Connection Power Output Connection M3 U Power Output Connection M2 V Power Output Connection M1 W Main Fan Housing PE Ground Connection Lifting eyes See Note 1 PE Ground Connection...

Page 9: ...or M1 M2 M3 L 3 Power Supply Cable L1 L2 L3 N Vent Kit with optional Drive Brake Unit P Fuse or Circuit Breaker R AC Line Choke T Auxiliary Supply V External Fan Frame J Permanent Earthing Each unit m...

Page 10: ...wings in the Engineering Reference manual for more information Models Maximum Weight kg lbs A B C D E F G H Frame G 32 5 72 102 4 0 125 4 9 251 9 9 57 2 2 575 22 6 340 13 4 300 11 8 420 16 5 Frame H 4...

Page 11: ...outlet duct The top vent is then mounted on to the outlet duct It is very important that the gasket for the vent is correctly fitted to the brake exhaust outlet duct Otherwise hot exhaust air will fl...

Page 12: ...and could result in catastrophic failure of the drive Main Cooling Fan and Supply Requirements The Frame G and H drives have an integral main cooling fan However the Frame J drive has a separate main...

Page 13: ...EMC filter For installations to EN 60204 in Europe Refer to Appendix C Certification for the Drive EMC Installation Options in the Engineering Reference Manual Permanent Earthing Each unit must be per...

Page 14: ...Analog This is a basic connection diagram For more detailed information on control connections refer to Appendix B DRIVE HEALTH Relay dry contact 24V rated at terminal X14 01 and terminal X14 02 RUNN...

Page 15: ...r direction to the motor direction When TRUE changes the sign of the measured speed and the direction of the position count It is necessary to set up this parameter when in CLOSED LOOP VEC mode as the...

Page 16: ...rection will not result in damage bodily harm or injury Disconnect the load from the motor shaft if possible Check the state of the Motor Thermistor and Brake Resistor connectors Check external run co...

Page 17: ...intended operating mode x x x Max Speed Motor RPM at full process speed x x x V F shape Usually Linear Choose fan curve only for fans x Motor Current Motor full load current from motor nameplate x x...

Page 18: ...rrors if autotune is successful Go to SYSTEM SAVE CONFIG APPLICATION and UP arrow to save your settings This section is only for operating in Sensorless or Closed loop Vector modes If the drive is in...

Page 19: ...Setpoint The value displayed depends on the external speed reference Dial in a speed setpoint using the Speed potentiometer until the display reads 20 Start the drive by closing the Start contact betw...

Page 20: ...Edit stop editing show PREF hold increment value decrement value To change Operating Mode From power up the keypad displays the Software Version and then times out to show the Remote Setpoint Mode Act...

Page 21: ...vel 1 QUICK SETUP menu at level 1 SETUP menu at level 1 SYSTEM menu at level 1 DOWN arrow to get to the SETUP menu contains all the parameters DOWN arrow to get to the SYSTEM menu DOWN arrow to get to...

Page 22: ...21 Appendix B Analog and Digital I O The terminal function names apply to the factory shipping configuration These terminals may have different functions if the configuration has been modified using...

Page 23: ...Page 22 890SD Control Terminals...

Page 24: ...Page 23 Appendix C Electrical Ratings Notes for Electrical Ratings Tables...

Page 25: ...Page 24 Electrical Ratings 890SD Frame G 400V...

Page 26: ...Page 25 Electrical Ratings 890SD Frame H 400V...

Page 27: ...Page 26 Electrical Ratings 890SD Frame J 400V...

Page 28: ...when handling installing and servicing this product EMC Emissions Conducted Emissions comply with EN61800 3 category C3 when installed in accordance with instructions in Chapter 4 5 refer to mounting...

Page 29: ...0 25 meters for runs longer than 10 meters separation should be increased proportionally Sensitive cables should cross noisy cables at 90 Never run sensitive cables close or parallel to the motor dc...

Page 30: ...ker hungary parker com IE Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN India Mumbai Tel 91 22 6513 7081 85 IT Italy Corsico MI Tel 39 02 45 19 21 parker italy parker com JP Japan T...