![Parker 598P Applications Manual Download Page 21](http://html.mh-extra.com/html/parker/598p/598p_applications-manual_755627021.webp)
15 of 20
598P/599P Application Manual
Version 2
In version 2 the PCB has been re-tracked on a different software package and the components updated to
Standard Parts. This gives the following differences.
1)
The PCB is slightly narrower (79mm) but fits on the same fixing centres;
2)
Terminal Block A is split into two parts A1 to A4 and A5, A6 & Earth. This is to enable the use of the
Relay on AC Supplies up to 240 Vac where previously clearances were inadequate;
3)
There is now an extra terminal between A6 7 Earth which is unused;
4)
Radial Electrolytic Capacitors are used instead of Axial;
5)
The add-on modification has been incorporated into the Circuit.
The functionality of the PCB is the same as before.
C1
C2
C3
C4
A1
A2
A3
A4
A5
A6
K K G
0V
0V
+24V
+24V
Relay
Relay
Signal
Signal
+24V
+24V
Signal from
Trigger Board
24V External
Supply
Thyristor
Trip Interlock
Closed when
External Supply On
> 2 amp
+24V Supply On
58mm
79mm
135mm
150mm
6.5mmDia
Transformer Earth Screen
Gnd
Cascade Signal
to extra
Amplifiers for
Parallel Stacks
Unused
This manual was downloaded on www.sdsdrives.com