62
WVM_BASIS_EN_03—07/2016
Fill quantities
Dessicant
B1
B2
Top
Silica gel
Silica gel
Bottom
waterproof Silica gel
waterproof Silica gel
Note on load cycle calculation:
According to the EC pressure equipment directive the dryers are rated
for 14,000 load cycles. This corresponds to a service life of approx. 20
years when operated in the fixed cycle of 6 hours (12 h total cycle
time). 1 load cycle corresponds to the change from the unpressurised
state to operating pressure.
When the pressure vessels are approved according to other
regulations, different load cycle calculations apply accordingly.
Typ WVM 40 – WVM 1450
Fluid class (according to PED)
2
Supply voltage
see type plate
Protection class
IP 54
min
max
Operating overpressure (bar)
see type plate
Ambient temperature (°C)
1
50
Max. intake temperature for regeneration air (°C)
(please heed the table below that relates the moisture of the intake air to the
temperature)
1
40
ax. dust contents of the regeneration air (mg/m³)
*
—
50
Noise level : +3 dB (A) related to free-field measurement, 1 m surrounding
field db(A)
75
90
*
Note: Provide for an appropriate dust filter when the regeneration air taken in
has a higher dust load. Contact the manufacturer in this case!
Regeneration air – maximum relative humidity at defined intake temperature
max. rel. humidity (%)
at intake temperature (°C)
90
20
70
25
50
30
37
35
25
40