66
HDK-MT350_EN_06
Technical data
Scope of application
Installation location
Interior installation, above freezing level, in non-
aggressive atmosphere
Ambient temperature
1.5 to 50 °C
Compressed air inlet temperature
30 to 55 °C
Operating pressure,
minimum/maximum
—
HDK-MT, pressure level 100 bar
—
HDK-MT, pressure level 350 bar
min. 50 bar, max. 100 bar
min. 100 bar, max. 350 bar
Fluid medium
Compressed air and gaseous nitrogen
Fluid group
(as per Pressure Equipment
Directive)
2
Electrical connection
Mains voltage, standard
230 V, 50-60 Hz
Alternative mains voltage
115 V, 50-60 Hz
Protection class
IP65
Please note type plate and attached electrical circuit diagram!
Noise emission
Sound level: +3 dB (A)
1
95 – 115 dB(A)
1
related to free field measurement, 1 m field
Dimensions
Please observe the dimensional drawing and table with dimensions and weights on page
Desiccant layers
Layer
Desiccant
Top
Molecular sieve
Middle
Silica gel (waterproof silica gel)
Bottom
Ceramic beads (Duranit)