![background image](http://html.mh-extra.com/html/parker-zander/hdk-mt-15-100/hdk-mt-15-100_operating-instructions-manual_756525003.webp)
Piping (100 / 350 bar)
Dryer
Allowable
pressure (PS)
Dimensions
(DN)
Category
(PED)
Module
HDK-MT 15 / …
400
DN15
Art.4.3
Art.4.3
HDK-MT 20 / …
400
DN15
Art.4.3
Art.4.3
HDK-MT 25 / …
400
DN15
Art.4.3
Art.4.3
HDK-MT 30 / …
400
DN15
Art.4.3
Art.4.3
HDK-MT 40 / …
400
DN20
Art.4.3
Art.4.3
HDK-MT 50 / …
400
DN20
Art.4.3
Art.4.3
HDK-MT 70 / …
400
DN20
Art.4.3
Art.4.3
Filter
Dryer
Filter Quantity
Allowable
pressure (PS)
Volume
[l]
Category
(PED)
Module
HDK-MT 15 / 100
GH7
2
100
0,52
I
B+D
HDK-MT 20 / 100
GH7
2
100
0,52
I
B+D
HDK-MT 25 / 100
GH7
2
100
0,52
I
B+D
HDK-MT 30 / 100
GH7
2
100
0,52
I
B+D
HDK-MT 40 / 100
GH9
2
100
1,33
I
B+D
HDK-MT 50 / 100
GH9
2
100
1,33
I
B+D
HDK-MT 70 / 100
GH9
2
100
1,33
I
B+D
HDK-MT 15 / 350
GH7
2
350
0,52
III
H
HDK-MT 20 / 350
GH7
2
350
0,52
III
H
HDK-MT 25 / 350
GH7
2
350
0,52
III
H
HDK-MT 30 / 350
GH7
2
350
0,52
III
H
HDK-MT 40 / 350
GH9
2
350
1,34
III
H
HDK-MT 50 / 350
GH9
2
350
1,34
III
H
HDK-MT 70 / 350
GH9
2
350
1,34
III
H
The following standards / technical specifications were used:
Harmonized standards: DIN EN ISO 12100:2011-03, DIN EN 61000-6-3, DIN
EN 61000-6-4
The following other EC directives were used:
2014/30/EU
2014/35/EU
Essen
,
19.07.2016
Datum / Date
i. V. Dr. Jürgen Timmler
Leiter Technik und Entwicklung /
Manager Engineering and Development