Page 70/71
9.3
Exchangeable coin box failure code
In case of exchangeable coin box failure:
If the terminal is equipped with several means of payment, the collection failure LEDs are
green
.
Payment by coins is impossible, but payment by card is available.
If payment by coins is the only means of payment available, the respective LEDs are
red
.
Code
Failure message
Problem
Solution
9001
MCB COMM. DEFAULT
Communication
problem
between the CP and the coin
box.
Contact the technical service.
9003
MCB LOCK. DEFAULT
The coin box cannot lock the
actuator.
Contact the technical service.
9004
MCB UNLOCK.
DEFAULT
The coin box cannot unlock
the actuator.
Contact the technical service.
9005
TM MCB DEFAULT
The coin box does is not
detected
although
the
trapdoor is closed.
End collection.
This failure is automatically
cancelled when a collection
ends
correctly
(coin
box
present and trapdoor closed).
9006
MCB SENSOR DEFAULT
The coin box sensors are
faulty.
Contact the technical service.
9007
MCB TRAPDOOR
DEFAULT
The trapdoor is not closed.
Contact the technical service.
9008
MCB PROG. DEFAULT
The
coin
box
was
not
programmed correctly.
Contact the technical service.
9009
MCB FRAUD DEFAULT
The coin box sensors have
changed states outside a
collection sequence; a fraud
attempt can be assumed.
Contact the technical service.
900A
MCB COLLECTION
UNFINISHED DEFAULT
The main board supply was
cut
during
a
collection
sequence.
Contact the technical service.