9.
Warnings and failures
9.1
Green warning LED
A green flashing LED is an early warning signal that
does not
put the parking terminal out of order. It indicates that
an intervention is required, for instance low ticket stock or low battery charge.
The green warning LED also blinks but less quickly to indicate that the terminal is operational even if the
display is in standby mode.
Display and cancellation of a warning:
It is possible to view the
"DIAGNOSTICS"
code in hexadecimal corresponding to a warning or a failure without
opening the maintenance door.
Press simultaneously the "Cancellation" (red) and "Validation" (green) buttons on the keyboard.
Hold the "Cancellation" button until the "Release change button" message appears.
Press the "Validation" button as many times as necessary to put the cursor on the "Errors" function in the
menu displayed.
Press the "Cancellation" button to select the function.
The terminal displays the list of the 20 most recent defaults and failures.
You can also open the maintenance door and use the keyboard to select the onsite programming function
97
.
Code
Warning message
Problem
Solution
4003
C
HARGING BATTERY
DEFAULT
The voltage of the battery is
low when in operation.
Replace the battery.
4004
I
DLE BATTERY DEFAULT
The voltage of the battery is
low when idle.
Replace the battery.
4005
S
UPPLY DEFAULT
The voltage of the battery is
insufficient.
Replace the battery.
4100
C
OIN BOX FAILURE
The number of coins in the coin
box exceeds the limit.
Collect the coins.
4108
P
AYMENT BY COINS
DEFAULT
The number of coins in the coin
box exceeds the threshold.
Collect the coins.
4206
T
ICKET NUMBER BELOW
The number of remaining
tickets is below the threshold
set by function 14.
Replace the ticket roll or
modify the threshold.
After the intervention, use the "DIAGNOSTICS" function to cancel the warning message.