TO COMPLETE INSTALLATION YOU WILL NEED THE FOL-

LOWING ITEMS (NOT INCLUDED)

(1) Six (6) feet 1/2” non-metallic conduit outdoor rated.

(1) 1/2" conduit compression fitting.

5

For technical assistance call 1.800.621.5886 or contact your regional representative

SELECTING LOCATION & MOUNTING UNIT

1.

Select a location on a wall near the pool equipment or insert posts into the
ground, which will be used to hang unit. The Clear O3

®

unit should be at least

one (1) foot above maximum water level, and for extra safety the unit should
be mounted higher than the filter. The unit should be within five (5) feet of an
electrical source, and within nine (9) feet of plumbing connection. A solid
surface is necessary to mount unit. Mounting brackets are horizontally
adjustable to line up with hard points on the mounting surface. The unit must
be mounted horizontally and level on the wall. Electrical connections should
be facing downward.

2.

Use provided screws and plastic wall inserts 
or poles and pole mount clamps (not included) depending on installation
surface available.

3.

Four (4) mounting
brackets are
included (two for the
top slot and two for
the bottom slot.

4.

Install anchors and
screws in desired
location for the top
hangers. They must
be no further apart than twelve (12) inches. Do not tighten screws all the way.

(Fig. 1)

5.

Hang the Clear O3

®

from the two top brackets by sliding the keyhole slots

over the screws.

Fig. 1: 

12" Maximum

Summary of Contents for Clear 03

Page 1: ...Toll Free 1 800 621 5886 Phone 480 893 7607 Fax 480 753 3397 Paramount 1Paramount com www 1Paramount com 004 027 8780 00 REV110711 US Patent 7 837 951 MADEINUSA WATER PURIFYING SYSTEM INSTALLATION MAN...

Page 2: ...electrical hookup Turn off power at main source before making any electrical connections or servicing the unit Use only liquid tight flexible nonmetallic conduit for electrical connections A terminal...

Page 3: ...e 1 foot above maximum water level to prevent water from contacting electrical equipment Install in accordance with the installation instructions Short term inhalation of high concentrations of ozone...

Page 4: ...bined chlorines like chloramines which do not sanitize and have adverse effects on human skin Use of ozone allows the chlorine to work primarily as a water disinfectant Pool water treatment can be bro...

Page 5: ...source and within nine 9 feet of plumbing connection A solid surface is necessary to mount unit Mounting brackets are horizontally adjustable to line up with hard points on the mounting surface The u...

Page 6: ...all anchors 8 Place the Clear O3 unit back on the screws and line up the two lower brackets with the wall anchors Fig 3 9 Install the bottom two screws and tighten all screws SELECTING LOCATION MOUNTI...

Page 7: ...G Turn off power at main source before making any electrical connections or servicing the unit 1 A licensed electrician should make all electrical connections Make sure the unit is grounded by connect...

Page 8: ...iltration pump time clock The ballast may be switched to 120VAC if needed Fig 7 See wiring diagram Fig 4 Go to page 21 23 for complete instructions on changing the ballast setting MAKING ELECTRICAL CO...

Page 9: ...e filter pump is off and not pulling air through the unit 5 Use external ground lug to connect the Clear O3 to the pool pump ground bond Fig 8 6 Turn on power to filtration system pump Check glow tube...

Page 10: ...ndard with Clear O3 and others are available to order seperately 2 2 Remove strainer pot plug If there is an O Ring on plug take O Ring off of pot plug and slide over threaded end of check valve 2 3 W...

Page 11: ...Glue a 3 4 elbow and a 3 4 x 1 4 NPT reducer bushing on end of standpipe 3 3 Install the threaded end of the check valve included in the reducer bushing 3 4 Install 3 8 OD x 1 4 ID tubing to barbed e...

Page 12: ...ve fully open 4 5 Note the filter pressure Then close the valve slightly until the pressure on the filter drops two or three psi 4 6 Go to setting the airflow on page 16 to finish setting airflow The...

Page 13: ...representative 5 Lay the 3 8 tubing along desired route to the compression fitting on the combination needle valve flow meter on the Clear O3 unit 6 Connect the tubing to the compression fitting Fig...

Page 14: ...alve and one tee on the suction side of the pump and one tee and valve on the return side of the pump before the heater Fig 17 2 Plumb inch PVC from pressure side tee into a union ball valve Fig 18A 3...

Page 15: ...direction of flow through the check valve Fig 19A 19B 6 Connect the tubing to the compression fitting Fig 20 7 Connect the compression fitting to the flow meter Fig 21 OPTIONAL SUBMERGED EQUIP INSTALL...

Page 16: ...RAMOUNT IN FLOOR SYSTEM lock the water valve on pause when the valve is switching ports and therefore at it s maximum flow the pause control is located on top of the Paramount water valve Set the flow...

Page 17: ...is vented from the filter when the pump is running You must install an external air bleed if the filter is old does not have an internal air bleed there is a solar system on the pool or there is a rob...

Page 18: ...e Make sure the gasket is in place between the fitting and the pipe Fig 24 Pg 17 13 Lay the tubing along the return pipe to the saddle clamp fitting and cut off excess length 14 Connect the end of the...

Page 19: ...r regional representative 1 Turn the power off to filtration system pump at circuit breaker 2 Remove three screws in left end side cap labeled electrical connections Fig 25 3 Remove side cap Fig 26 4...

Page 20: ...is in place on replacement light bulb 8 Align with key and slide into hole until bulb seats firmly and completely into unit Fig 30 9 Press plug onto light bulb 10 Replace side cap and three screws 11...

Page 21: ...at strainer pot 3 Light bulb does not light Check power to Clear O3 then replace bulb at the breaker and remove the unit from wall mounting 2 With a Phillips screwdriver remove the three 3 screws in...

Page 22: ...Pull the light bulb from the unit 7 With a Phillips screwdriver remove the two 2 screws inside the electrical housing next to the light bulb hole that connect the electrical housing to the aluminum ho...

Page 23: ...s screwdriver while holding the lock nut on the inside of the cavity with pliers Fig 36 11 Pull the ballast plate free from housing 12 On the side of the ballast is a switch to select voltage Push the...

Page 24: ...CLEAR 03 WATER PURIFYING SYSTEM 24 For technical assistance call 1 800 621 5886 or contact your regional representative 5 1 2 8 4 6 12 10 11 3 9 7 14 13 16 18 optional optional optional 17 15...

Page 25: ...g Harness 3 Wire 12 Gauge X 6ft 7 005 402 3361 00 Tubing with Check Valve Pump Mount Wire Ties 8 Tubing 3 8 OD X 1 4 ID X 10ft 9 Pump Mount Check Valve 1 4 NPT x barb 10 Wire Ties 4 pk 11 005 402 3247...

Page 26: ...ll the repaired or replaced item is the sole responsibility of the owner LIMITATIONS No warranty extends to any part of the PP SS parts or components which is caused by any of the following conditions...

Page 27: ...PV3 Pool Valet Cyclean Vanquish Vantage Ecopool POOL BUILDER INFORMATION Name Address City State Zip Code When complete remove this page fold stamp and return to Paramount Pool Spa Systems Postal Serv...

Page 28: ...Paramount Pool Spa Systems 295 East Corporate Place Suite 100 Chandler AZ 85225 Staple Here Place Stamp Here Fold Here Cut Here and Return to Paramount...

Reviews: