background image

12 

Risk Assessment 

The following risk assessment covers the reasonably foreseeable hazards to health and safety arising from 

the mixer and from systems of work associated with this machine. 

Risk Rating 

Extreme Risk 

Immediate action required. 

 

High Risk 

Senior management attention required. 

 

Moderate Risk 

Management responsibility must be specified. 

 

Low Risk 

Manage by routine procedures. 

Based on AS4360 1999 Risk Management. 

Hazard Identified 

Existing Controls 

Consequences 

Likelihood  Risk Rating 

Cleaning the machine with buckets of 
water or hoses is extremely dangerous 
and may lead to electrocution.  The  
machine must be cleaned with a damp 
cloth only. 

Safe work cleaning practices 
included in training manual 
local workplace rules and 
management. 

Catastrophic 

Rare 

High 

Microswitch on safety guard should never 
be removed nor tampered with otherwise 
machine could continue working with 
moving parts exposed. 

Safe work guidelines  
reinforce non-authorised 
tampering with the machine.  
Access to microswitches 
service  item only. 

Major injuries 

Rare 

Moderate 

Electrical isolation switch should be fully 
accessible to the operator.  Recommend 
no more than 1.5 metres above the floor 
and within easy access by the operator. 

Dependent on bakery  
electrical policy. 

Major injuries 

Rare 

High 

Safety guard should not be removed. 

Microswitch interlocked with 
machine - controls will not 
operate. 

Major injuries 

Unlikely 

Moderate 

Service panels should not be removed 
whilst the machine is in operation nor still 
connected to the power supply.  The  
machine must not be operated with any 
service access panel removed. 

Machine designed to be  
accessed by authorised  
service technicians only.  
Warning signs clearly  
evident. 

Major injuries 

Unlikely 

Moderate 

Hands or arms should not be placed  
behind bowl whilst the machine is in  
operation. 

Safe operating procedure 
reinforces this not to be 
done.   
Warnings in place. 

Minor injuries 

Unlikely 

Low 

Hands should never be placed near dough 
hook whilst in motion. 

Bowl guarded during  
operation.  Safe operating 
procedures highlight safe 
work. 

Major injuries 

Unlikely 

Moderate 

Cleaning of the machine should not take 
place whilst it is in operation nor still  
connected to the power supply. 

Correct cleaning procedure 
detailed in training  
procedure. 

Major injuries 

Unlikely 

Moderate 

The machine should never be connected 
to alternate power source other than that 
which it has been designed for and  
specified within this manual. 

External plug designed to 
Australian / New Zealand 
standards for the appropriate 
power supply.  Warnings in 
manual. 

Major injuries 

Rare 

Moderate 

Owners and Operators of Paramount Equipment Please Note: 
The risk ratings and control measures as outlined in this manual must be incorporated into your safety 

management systems and procedures.  Ensure effective risk control by reinforcing these procedures with 

staff.  For example:  Never clean any electrical equipment with buckets of water or pressurised hoses. 

Summary of Contents for BM60

Page 1: ...1 BM60 Planetary Mixer INSTALLATION OPERATION MANUAL F26295 6...

Page 2: ...vice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Li...

Page 3: ...n 5 Cleaning and Maintenance 7 Fault Finding 8 Competency Checklists 9 Operations Competency Checklist Daily Cleaning Competency Checklist Risk Assessment 12 Replacement Parts List 13 Wiring Diagrams...

Page 4: ...a hardened steel worm wheel A stainless steel safety guard and electronic timer are available on all models With proper operation and maintenance this mixer will give you years of service and obtain t...

Page 5: ...hen the desired time has elapsed Emergency Stop Button Located on the Control Panel on the right hand side of the machine Pressing this button will stop all movement of the machine The Emergency Stop...

Page 6: ...ssary in normal installations Floor models must be leveled front back and side to side by sliding shims under the legs as required Electrical Connection The supply cord on this machine is provided wit...

Page 7: ...s elapsed In timed operation if the machine is shut off before the preset time has elapsed the electronic TIMER does not continue To restart mixing the electronic TIMER has to be reset then depress th...

Page 8: ...bottom Agitators When placing an agitator on the agitator shaft lower the bowl push the agitator up onto the shaft and turn the agitator until the drive pin on the shaft reaches L shaped slot in the a...

Page 9: ...ard should be removed periodically and wiped clean Maintenance Guidelines The Transmission Case and Planetary Mechanism should be inspected weekly for leaks damage etc Should it become necessary to re...

Page 10: ...s are Off at the power board The mixer electronic timer is set to 0 Turn On Set time setting or set electronic timer to 0 to allow manual operation Mixer stops during operation Mixer overload tripped...

Page 11: ...be completed signed and a copy kept in the personnel files for future reference Supervisors to Ensure Competency check lists are copied and completed as part of the training of staff Correct training...

Page 12: ...s Identify OH S reporting procedures related to hazard reporting for this machine Comments To gain competency in the use of the PARAMOUNT PLANETARY MIXER the assessor must be satisfied that the operat...

Page 13: ...ygiene and sanitation Actual and potential contamination and spoilage hazards Solutions to rectify contamination and spoilage problems Use work practices and methods that reduce the risk of product co...

Page 14: ...operate Major injuries Unlikely Moderate Service panels should not be removed whilst the machine is in operation nor still connected to the power supply The machine must not be operated with any serv...

Page 15: ...M60AT 12 004 Stainless Steel Wire Whip BM60AT 12 002 Batter Beater BM60AT 06 003 HUB Attachment Drive HL GL12SH Mincer HL VS12A Slicer Shredder BM60ATM 30 litre Reduction Kit includes Bowl Hook Beater...

Page 16: ...14 Wiring Diagrams Single Phase Models Three Phase Models...

Page 17: ......

Reviews: