Option 2 (standard equipment from s.n.1882867 – Ø78x375 BA Filter):
1.
Unscrew filter’s housing together with head counter clockwise.
2.
Remove the filter’s housing together with head.
3.
Remove the A.C.-M.S. cartridge
.
Before throwing away the used cartridge, do not forget to remove the cartridge
connector.
4.
Clean the inside of the filter housing with a clean cloth.
5.
Remove the new A.C.-M.S. cartridge from their protective case. Be sure that packaging is not punctured. If it is
damaged do not use it.
6.
Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
7.
Replace the two o-rings of the cartridge connector, lay a small amount of silicone grease on the new o-rings and then
screw the connector on the new A.C.-M.S. cartridge.
8.
Place the new A.C.-M.S. cartridge in the filter housing and fasten it down by hand on the coalescing connector.
9.
Screw the filter housing carefully by hand with light pressure until it fits evenly to the filter housing.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.
FILTER HEAD & FILTER HOUSING SHOULD BE ADJOINED ON TOP WHEN REINSTALLING.
Active carbon – molecular sieve cartridge replacement