599 Menlo Drive • # 100 • Rocklin, CA 95765
Sales / Technical Support - Tel: (916) 624-8333 Fax: (916) 624-8003
Web: http://www.parallaxinc.com or http://www.stampsinclass.com • Email: [email protected]
1-27-2000, V1.0 • Mfg. by www.
RFDigital.com
Page
10
RF MODULES
Use the Basic Stamp 2 or BASIC Stamp 2sx’s SERIN and SEROUT commands to send and receive 9600, N, 8,
1 bytes. The modules can not send and receive continuous 9600 baud serial data. If the Flow Control (TXFLO)
will not be used for sending serial data (TXD), you must have at least 15 milliseconds spacing between the start
of each byte. Refer to the SERIN and SEROUT commands in the Basic Stamp Manual for more information.
TXD, TXFLO and RXD pins are +5V logic. THEY DO NOT SUPPORT RS232 VOLTAGE LEVELS.
Do NOT connect directly to RS232 port.
Hook-up Using Serial Mode