7300 Series 

DC Wiring

1.

Converter DC output lead.

2.

Converter “reverse battery polarity” 
protection fuses.

3.

“C” Terminal – Connect to battery 
Positive wiring. # 8 CU AWG 
minimum w/ 90 degree Celsius 
insulation rating required.

4.

“D” Terminal – Connect to 12 volt 
load Negatives and battery Negative. 
# 8 CU AWG minimum w/ 90 degree 
Celsius insulation rating required.

5.

12 Volt load circuit Positive 
connection terminals. Fuse each load 
circuit per NEC Code (Table 310-16) 
appropriate to AWG and temperature 
rating of conductor  used.

12 VDC installation shall comply with 
ANSI/RVIA 12 V

GR series terminal bar 
recommended.

DC load circuits

+

+

1

2

3

4

5

+