background image

1-800-443-4859

The Power to Bring People and Places Together !

All information, drawings, flowcharts, and schematics are the 
property of Parallax Power Supply L.L.C. All rights reserved. 
Refer installation and servicing to qualified service 
personnel. Service information provided solely for use by 
Licensed Electricians and Certified RV Technicians. No 
endorsement of technical expertise, arising from the use of the 
information supplied is either expressed or implied. 

7300 Series Wiring Labels

DC Wiring Label

(located inside door right side)

12 VDC installation shall comply 
with ANSI/RVIA 12 V.

Fuse Diagram

Replace with Little Fuse type 257 fuse

Or Bussmann type ATC fuse.

Max. Reverse Polarity Protection

 Fuse size: 30A

A: AC DISTRIBUTION PANEL
    This panel contains the AC breakers for each of the 120 VAC branch circuits 

of the RV. To turn AC breakers ON or OFF, switch breaker handle. Breaker 
posistion is indicated by visual ON, OFF. To reset a tripped breaker, switch 
breaker handle OFF, then ON

B: DC DISTRIBUTION PANEL

    This panel contains the 12 volt DC fuses for each of the 12 VDC load circuits 
of the RV. The DC distribution panel is designed for blade type fuses with a 

maximum size of 20 amperes. If a fuse blows, do not replace with a fuse larger 

than indicated on the label.

C: Power Converter - 120 VAC TO 12 VDC

    When 120 VAC is connected to the Power Converter section either via 

commercial power or generator, the converter will automatically provide the 12 
volt DC power to operate the 12 volt DC power lights and 12 volt DC motors in 
the RV. When 120 VAC is not connected to the Power Converter section, the RV 
storage battery(ies) automatically provide the necessary 12 volt DC to operate 
this equipment.

D: BATTERY CHARGING SECTION

    When 120 VAC is connected to the Power Converter section, the total DC 

amperage output of the converter is available for recharging the RV battery(ies), 

minus current used by 12 volt load equipment.

E: INSTALLATION REQUIREMENTS (HORIZONTAL MOUNTING ONLY)

    Mount the series 7300 Power Plus Control to a verticle surface with the 
front of the control center open to the living area of the RV. Leave adequate 

room for ventilation and wire routing.

A: CONVERTER OUTPUT: CKTS 1 - 9   VDC Positive load circuits for RV 12 volt loads. 

DO NOT USE HIGHER THAN 20 AMPERE FUSE.
B: REVERSE BATTERY POLARITY PROTECTION FUSES. REPLACE WITH 30 

AMPERE MAXIMUM.

C: LUG FOR POSITIVE LEAD OF 12 VOLT BATTERY. Use  #8 AWG CU conductor 

with 90 degree Celcius insulation rating minimum.

D: LUG FOR NEGATIVE LEAD OF 12 VOLT BATTERY. Use  #8 AWG CU conductor 

with 90 degree Celcius insulation rating minimum.

CAUTION:

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE 

OR ELECTRIC SHOCK, REPLACE ONLY WITH SAME 
RATINGS AND TYPE OF FUSE.

51092338-000

Maximum branch Circuit Fuse size: 20 A