12
LT6757 ( Iss 1 06/14 )
P7 Installation Instructions
SECTION SIX Appliance Data
NATURAL GAS
Gas Type:
CATEGORY I 2 H
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
7.0 kW Gross (Max.)
2.4 kW Gross (Min.)
Injectors:
Mk 460
Oxy pilot:
9079 N.G.
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location:
Located on the base of the appliance on the L/H side beneath the grill.
Battery Remote handset
2 x 1.5 AAA
Appliance 6 x 1.5V AA high power alkaline.
Appliance Dimension
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009+A1 : 2013 and the result is 60.2 %. The gross calorific value
of the fuel has been used for this efficiency calculation. Gastec have certified the test data from which it has been calculated. The efficiency value may
be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
Please note:
Within the appliance packaging
will be a outlet restrictor, this is there to achieve the maximum efficiency. This, however, may not be fitted due to the flue underperforming.
Fireplace Frame Option
Four Sided Trim Option