Messages and Troubleshooting
6-5
7986-A2-GB20-00
September 1998
Troubleshooting
This Model 7986 Standalone Termination Unit is designed to provide you with
many years of trouble-free service. If a problem occurs, however, refer to
Table 6-2 for
possible solutions.
Table 6-2.
Troubleshooting (1 of 2)
Symptom
Possible Cause
Solutions
Alarm LED is on.
One of several alarm
conditions exists. Health
and Status displays the
alarm condition.
Refer to Table 4-1,
Health and Status
Messages
, for recommended action.
Cannot access the
unit via the ATI.
The terminal is not set up
for the correct rate or data
format, or the unit is
configured so it prevents
access.
H
Check the cable and connections.
H
Ensure the unit is configured
properly. Verify IP address and
communication port usage.
H
Reset the unit.
Device Fail appears
on the System and
Test Status screen
under Self-Test
results.
The unit detects an internal
hardware failure.
H
Reset the unit.
H
Contact your service
representative.
No power, or the
LEDs are not lit.
The power cord is not
securely plugged into the
wall receptacle and into the
rear panel connection.
Check that the power cord is
securely attached at both ends.
The wall receptacle has no
power.
H
Check the wall receptacle power
by plugging in some equipment
that is known to be working.
H
Check the circuit breaker.
H
Verify that your site is not on an
energy management program.
Power supply has failed.
Replace power supply.
An LED is not lit.
LED is out.
Run the Lamp test. If the LED in
question does not flash with the other
LEDs, then contact your service
representative.
Summary of Contents for Hotwire 7986 M/HDSL
Page 68: ...Testing 5 10 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 80: ...Security 7 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 106: ...Standards Compliance for SNMP Traps B 6 7986 A2 GB20 00 September 1998...
Page 114: ...Technical Specifications D 2 7986 A2 GB20 00 September 1998 This page intentionally left blank...