Connecting Power to the Unit
If your package includes a power pack: Plug the power pack into an ac outlet
having a nominal voltage rating between 100–240 Vac. Connect the output cable
of the power pack to the connector marked POWER on the rear panel.
If your package includes a direct-connection dc power cable: Connect the unit to
an external dc power source as described in
Connecting the Unit to an Optional
External DC Power Source
.
Optional Power Sources
Using the optional dc power cable, the unit is capable of operating on a +24 Vdc
power source. To select the power, choose one of the following power supply
types.
Connecting the Unit to an Optional External DC Power Source
Using the dc power cable, the Hotwire Model 7986 Standalone Termination Unit
is capable of operating on a +24 Vdc power supply.
NOTE:
The E1 M/HDSL Unit is typically powered by the ac power module. Use the
following procedures only if you want to use an optional dc power source.
"
Procedure
To use the dc power cable:
1. Connect the green wire to a suitable earth ground.
2. Connect the orange wire to the +24 Vdc source.
3. Connect the white wire to the return.
4. Cut the black, red, and blue wires off at the outer insulation.
5. Plug the power connector into the Model 7986 Standalone Termination Unit.
1
2
3
4
5
6
X
X
Earth Ground
RTN
+24 Vdc
X
Black
Red
Green
White
Orange
Blue
98-14158-01
+24 Vdc Power Supply Pinouts
Summary of Contents for Hotwire 7986 M/HDSL
Page 68: ...Testing 5 10 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 80: ...Security 7 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 106: ...Standards Compliance for SNMP Traps B 6 7986 A2 GB20 00 September 1998...
Page 114: ...Technical Specifications D 2 7986 A2 GB20 00 September 1998 This page intentionally left blank...