12
Setting Up Management
For remote sites, only SNMP management needs to be set up. For the central site,
local management between the unit and the router must be set up along with SNMP
management.
To set up SNMP management:
1. Select Management and Communication.
2. Select General SNMP Management.
3. Minimally, set Name 1 Access to Read/Write.
4. Save the configuration.
To set up local management at the central site unit:
1. Create a DLCI for the data port.
Configuration
→
Data Ports
→
DLCI Records
2. Save the configuration and return to the Configuration Edit/Display menu.
3. Select Management PVC.
Configuration
→
Management and Communication
→
Management PVC
4. Make the DLCI Record a management DLCI to create a Management PVC.
Minimally, enter the following options for each of the DLCI Records created:
– Name for the management DLCI.
– Special and the IP Address for the interface if it is different from the Node
IP Address.
– Primary Link for this DLCI (i.e., the DLCI’s primary destination interface).
– Primary DLCI (i.e., the DLCI number at the other end of the PVC).
5. Save the configuration.