19
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration
→
Network
→
DLCI Records
2. Select Modify. The
Modify DLCI Record for DLCI Number?
prompt
appears.
3. Select the DLCI that will be used by pressing the spacebar until the correct DLCI
number appears, then select it.
4. Change the DLCI Type from Multiplexed to Standard.
The
DLCI in connections. Update DLCI usage as follows:
prompt appears.
5. Select the
Delete EDLCI Connections and Make a Mgmt Only PVC
option.
6. Select Yes at the prompt.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to
this network DLCI and the embedded management DLCI (EDLCI) are deleted, and
the selected DLCI will be reconfigured as a management PVC using the Node IP
Address.
Verifying the End-to-End Path
After installation of a remote site unit, run an IP Ping test to ping the NMS at the central
site and verify that the entire path from the remote unit to the NMS is functioning. To run
the IP Ping test, NMS trap managers must have been configured for the remote unit.
One of those trap managers must be the central site NMS.
1. Select the IP Ping test.
Main Menu
→
Test
→
IP Ping
2. Enter the IP Address of the device being pinged, then select Start.
NOTE:
When running tests, the cursor is positioned over the Start command. Press
Enter to start the test. Stop is displayed while the test is running. Press Enter
again to issue the Stop command.
– While the test is running,
In Progress . . .
is displayed in the Status field.
– When the test is finished,
Alive. Latency =
nn ms
should appear as the
Status (
nn being the amount of time the test took in milliseconds).
If any other message is displayed, additional testing will be required. See
Device
Messages in Displaying System Information of the User’s Guide for information
about IP Ping-related messages.