Testing
6-5
7970-A2-GB20-00
August 1999
Send and Monitor 511
The LTU initiates the test by sending a command to the remote unit to send a
511 test pattern. When the remote unit detects the command, it sends a
511 pattern and lights the front panel TEST LED. Each unit will send and monitor
the 511 pattern. The duration and results of the test are displayed on the Network
Test screen of each unit.
NOTE:
The Send and Monitor 511 test is not a loopback test. Each unit
independently sends and monitors a 511 pattern.
CAP
DSX-1
Port
CAP
T1
LIU
Framer
Framer
Transceiver
98-16108
CAP
CAP
T1
LIU
Framer
Framer
Transceiver
AIS
AIS
511
Gen
511
Mon
511
Pattern
511
Pattern
511
Mon
511
Gen
"
Procedure
To run a Send and Monitor 511 test:
1. Position the cursor at the Start command next to Send and Monitor 511 on
the Network & DSX-1, Network, or Network & G.703 Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command and press Enter.
When a Send and Monitor 511 test is active, a count of bit errors appears next to
the test duration, and the ResetMon virtual function key is available for use. Type
r or R or select the ResetMon virtual function key to reset the error count.
Summary of Contents for 7984
Page 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Page 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Page 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Page 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999 ...