B-1
7970-A2-GB20-00
August 1999
Standards Compliance for
SNMP Traps
B
SNMP Traps
This section describes the unit’s compliance with SNMP standards and any
special operational features for the SNMP traps supported. The Hotwire 7974
Standalone Termination Unit supports the following traps:
H
warmStart
H
authenticationFailure
H
linkUp and linkDown
warmStart
SNMP Trap
Description
Possible Cause
warmStart
The unit has reinitialized
itself.
The trap is sent after the
unit resets and stabilizes.
There are no
variable-bindings.
H
Reset command.
H
Power disruption.
authenticationFailure
SNMP Trap
Description
Possible Cause
authenticationFailure
Failed attempts to access
the unit.
There are no
variable-bindings.
Three unsuccessful attempts
were made to enter a correct
login/password combination.