ACCULINK 3350 E1 NTU
4-20
June 1996
3350-A2-GB20-10
Aborting Test Patterns
Use the Abort command to stop all test patterns or any
selected test pattern active on the E1 NTU.
To abort test patterns,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
F1
Test:
Lpbk
Ptrns
Lamp
F2
F3
3. From the Patterns screen, select Abort.
F1
Patterns:
Abort
Send
Mon
F2
F3
4. From the Patterns Abort screen, press the desired
Function key to abort either All active test
patterns, active Send test patterns, or the active
Monitor (Mon) test pattern.
F1
Patterns: Abort
All
Send
Mon
F2
F3
The E1 NTU terminates the selected test pattern
and displays the message Command Complete.
NOTE
Be careful when selecting a specific
test pattern to abort. If you mistakenly
choose to abort a test pattern that is
not currently running, a Command
Complete message still displays and
the test pattern currently active still
runs. You can use the TStat branch of
the menu to view the test status to
determine if the abort was successful.