ACCULINK 3350 E1 NTU
3-14
June 1996
3350-A2-GB20-10
To select the link layer protocol,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
SNMP selection appears on the screen.
5. Select SNMP.
F1
Edit:
User
Alarm
SNMP
F2
F3
6. From the SNMP Config screen, select Gen.
F1
SNMP Config:
Gen
Trap
F2
F3
7. Press F1 (Next) until the Com Link configuration
option appears.
8. Press F2 (PPP) or F3 (SLIP).
F1
Com Link:
Next
PPP
SLIP
F2
F3
Specifying the Community Name(s) and
Access Type(s)
You have the capability of specifying up to two
community names (community name 1 and community
name 2) to be used by external SNMP managers when
trying to access objects in the E1 NTU’s MIB. Once you
specify the community name(s), you must then specify the
type of access to the MIB that SNMP managers in the
community are permitted to have.
To specify the community name 1 and its access type,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
SNMP selection appears on the screen.
5. Select SNMP.
F1
Edit:
User
Alarm
SNMP
F2
F3
6. From the SNMP Config screen, select Gen.
F1
SNMP Config:
Gen
Trap
F2
F3
7. Press F1 (Next) until the CommunityName1
configuration option appears.